background image

309319

English

Warnings

FIRE AND EXPLOSION HAZARD
Improper grounding, poor ventilation, open
flames or sparks can cause a hazardous condi-
tion and result in a fire or explosion and serious
injury.
To help prevent injury from fire or explosion

D

Provide fresh air ventilation to avoid the
buildup of flammable fumes from flushing fluids
or the coating being applied.

D

Keep the application area free of debris,
including solvent, rags, and gasoline.

EQUIPMENT MISUSE HAZARD
Misuse can cause the equipment to rupture or
malfunction and result in serious injury.
To help prevent injury

D

Do not modify the extension tube or roller
frame or use parts not designed for this
equipment.

D

Do not use 1,1,1–trichloroethane, methylene
chloride, other  halogenated hydrocarbon sol-
vents or fluids containing such  solvents in this
or any other pressurized aluminum equipment.
Such use could  result in a chemical reaction,
with the possibility of explosion.

ELECTROCUTION HAZARD
Failure to observe the electrical hazards
described below could result in serious injury,
including burns or electrocution.
To help prevent harmful electrical shock

D

Avoid contact with power lines.

D

Follow all grounding instructions in your
separate pump and gun instruction manual,
and comply with all local, state, and national
fire, electrical, and safety regulations.

D

Use only M

AGNUM

 or Graco paint hoses.

FLUID INJECTION HAZARD
If high-pressure fluid pierces your skin, the inju-
ry might look like “just a cut”. But it is a serious
wound. Get immediate surgical treatment.
To help prevent injection

D

Keep your hands and body away form the
roller frame when flushing. High pressure
fluid emitted from the holes in the frame
could cause an injection injury.

D

Always relieve pressure before  you check or
repair leaks and  when you turn off pump or stop
painting.

D

Never use components rated less than
system Maximum  Working Pressure.

WARNING

Additional Roller Covers

The following M

AGNUM

 pressure roller covers are

available at your local distributor:

243063

9 in. (23 cm); 1/2 in. (13 mm) nap

243064

9 in. (23 cm); 3/4 in. (19 mm) nap

243065

9 in. (23 cm); 1-1/4 in. (32 mm) nap

Installation

Assemble the pressure roller as shown in the Parts
Drawing
 on page 3.  Attach pressure roller assembly
to spray gun.

Pressure Relief Procedure

WARNING

To help prevent injection injuries,
follow this procedure whenever
you stop painting.

psi/MPa/bar

1.

Put gun trigger safety in SAFETY ON position.

2.

Shut off power to pump.

3.

Turn prime/spray valve to the PRIME position to
relieve pressure in system.

4.

Put gun trigger safety in SAFETY OFF position,
and trigger gun to relieve any pressure in hose.

5.

Put gun trigger safety in SAFETY ON position, and
keep pump prime/spray valve in PRIME position
until you paint again.

Operation

1.

Follow pump priming instructions using lowest
pressure setting at which pump primes.

2.

Turn prime/spray valve to SPRAY position.

3.

Disengage gun safety latch, trigger the gun, and
roll the surface until paint comes to roller.

NOTE:  Trigger the gun briefly only when you need
more paint. Determine how often you must trigger
the gun to maintain an even paint supply to the
roller.

4.

Increase pump pressure only if triggering gun
cannot supply enough paint for your rolling speed.

See Pressure Relief
Procedure
 on page 2.

5.

Whenever you stop painting, relieve the
pressure
, and elevate roller end of extension tube
to prevent paint from draining out.

Flush the pump, gun, and pressure roller immediately
after each use to prevent paint from drying in the
pressure roller and damaging it. See Cleaning on
page 2.

Cleaning

This is the procedure for flushing the pressure roller.
The pump and gun you are using may have additional
flushing steps, such as cleaning filters and screens.
See the pump and gun flushing instructions.

Содержание Magnum 244512

Страница 1: ...i 2 1 MPa 21 bar Employez la plus basse pression qui fournit une offre gale de peinture au rouleau en g n ral moins de 300 psi 2 1 MPa 21 bar Utilice la presi n m s baja que proporciona una fuente uni...

Страница 2: ...n you turn off pump or stop painting D Never use components rated less than system Maximum Working Pressure WARNING Additional Roller Covers The following MAGNUM pressure roller covers are available a...

Страница 3: ...pray valve to SPRAY NOTE Perform Step 7 at the lowest pressure possible 7 Trigger gun until flushing fluid begins to dilute the paint 8 Place roller frame 1 in another bucket and continue flushing unt...

Страница 4: ...de haute pression qui sort des orifices de l armature peut causer des blessures par injection D D charger toujours la pression avant de v rifier ou r parer une fuite arr ter la pompe ou arr ter de pei...

Страница 5: ...d amor age en utilisant de l eau ou un fluide de vidange pour enduits base d huile 6 Mettre le robinet d amor age pulv risation de la pompe la position SPRAY REMARQUE Effectuer l tape 7 la plus basse...

Страница 6: ...ir de los fluidos para el lavado o por el recubrimiento que se est aplicando D Mantenga el rea de aplicaci n libre de desechos incluyendo disolventes trapos y gasolina Cubiertas para rodillo adicional...

Страница 7: ...e la bomba con agua o l quido de lavado para materiales a base de aceite Utilice la configuraci n de presi n m s baja para el cebado de bomba 6 Ponga la v lvula de cebado pulverizaci n en la posici n...

Страница 8: ...Graco s Authorized Service Center at its option will either repair or replace the product and return it to you postage prepaid A listing of Authorized Graco Service Centers is enclosed with this produ...

Отзывы: