4
Application Methods
Calibration
Minimum 24 ft precision course
CALIBRATION
1. Lay out a steel measuring tape (minimum 25 ft, maximum 100 ft).
2. Line up the striper parallel to the tape measure with the LazerGuide 1700 Start/Stop Laser at the 1 ft mark.
3. Go to the
CALIBRATION
screen on the LiveLook display and select your calibration distance (24 ft in this
example).
4. Press the
REMOTE SWITCH
and move the LazerGuide 1700 Start/Stop Laser along the tape measure and stop
at the measurement 1 ft beyond the inputted measurement on the display to take into account that you started
on the 1 ft mark.
NOTE:
The LiveLook display is measuring in both the forward and backwards direction so if you go past the FINISH
point you can back up the striper before pressing the
GUN TRIGGER CONTROL
button to subtract from the mea-
surement.
5. To verify your calibration, go to measure mode (see page 5).
To calibrate LazerGuide 2000, see manual 3A5294 or the LazerGuide 2000 Setup & Calibration video.