Smart Control Operation
26
3A3393C Operation
5. Extend steel tape to distance greater than 26 ft.
(8m).
6. Press to
select
Setup/Information.
7. Press
for Calibration. Set TRAVEL DIST to 25
ft (7.6m) or longer. Longer distances ensure better
accuracy, depending on conditions.
\
8. Align part of the unit with 1 foot (30.5cm) on steel
tape.
9. Push gun trigger control to start calibration.
10. Move striper forward. Keep unit aligned with steel
tape.
11. Stop when chosen part of unit aligns with 26-ft (8m),
or distance entered, on steel tape (25-ft./ 7.6m dis-
tance).
12. Push gun trigger control to complete calibration.
•
Calibration is not complete when the exclamation
symbol
is
displayed.
•
Calibration is finished when the check mark symbol
is displayed.
13. Calibration is now complete.
Go to Measure Mode and verify accuracy by measuring
the tape (see
Measure Mode
, page 28).