![Graco King E50 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/graco/king-e50/king-e50_instructions-manual_2251568008.webp)
Installation
Installation
Installation
To reduce the risk of electric shock, fire and
explosion, all electrical wiring must be done by a
qualified electrician and comply with all local codes
and regulations.
Power
Power
Power Requirements
Requirements
Requirements
See Driver Installation manual for instructions for
power requirements.
Connect
Connect
Connect Power
Power
Power
See Driver Installation manual for instructions to
connect power.
Grounding
Grounding
Grounding
This equipment must be grounded to reduce the
risk of static sparking and electric shock. Electric
or static sparking can cause fumes to ignite or
explode. Improper grounding can cause electric
shock. Grounding provides an escape wire for the
electric current.
Sprayer:
Sprayer:
Sprayer: System is grounded through the power
cord.
Fluid
Fluid
Fluid hoses:
hoses:
hoses: Use only electrically conductive hoses
with a maximum of 210 ft. (64 m) combined hose
length to ensure grounding continuity. Check
electrical resistance of hoses. If total resistance
to ground exceeds 25 mega ohms, replace hose
immediately.
Spray
Spray
Spray gun:
gun:
gun: Ground through connection to a properly
grounded fluid hose and pump.
Fluid
Fluid
Fluid supply
supply
supply container:
container:
container: Ground the fluid supply
container. Follow local code.
Object
Object
Object being
being
being sprayed:
sprayed:
sprayed: Ground the object being
sprayed. Follow local code.
Solvent
Solvent
Solvent pails
pails
pails used
used
used when
when
when flushing:
flushing:
flushing: Follow local
code. Use only conductive metal pails, placed on
a grounded surface. Do not place the pail on a
non-conductive surface, such as paper or cardboard,
which interrupts grounding continuity.
To
To
To maintain
maintain
maintain grounding
grounding
grounding continuity
continuity
continuity when
when
when flushing
flushing
flushing or
or
or
relieving
relieving
relieving pressure:
pressure:
pressure: Hold the metal part of the spray
gun/dispense valve firmly to the side of a grounded
metal pail, then trigger the gun/valve.
1.
Loosen the ground screw (Y) and attach a ground
wire (Graco part 244524 – not supplied). Tighten
the ground screw securely. Connect the other
end of the ground wire to a true earth ground.
NOTE:
NOTE:
NOTE: Two ground terminals are provided if local
code requires redundant grounding connections.
2.
Ground the object being sprayed, fluid supply
container, and all other equipment in the
work area. Follow your local code. Use only
electrically conductive air and fluid hoses.
3.
Ground all solvent pails. Use only metal pails (5
gallon (19 liter) metal pail, Graco part 101108
– not supplied), which are conductive, placed
on a grounded surface. Do not place pail on
a non-conductive surface, such as paper or
cardboard, which interrupts grounding continuity.
8