Parts
333349E
3
9. Run wires/cabling from transformer enclosure (4)
through plastic cable bushing (3) into main electrical
enclosure.
10. Connect fan connector from transformer enclosure
into J7 on AWB.
11. Connect black wires from transformer enclosure (4)
to J2 on AWB board according to the table below:
12. Connect ground wire from the transformer
enclosure (4) into GND on J2 of AWB and main
enclosure ground (G).
13. Connect red wires from transformer enclosure (4) to
main power switch (H) according to the following
table:
14. Re-attach fan panel (155) to transformer
enclosure (4).
15. Replace front access panel on electrical enclosure.
Parts
400V Transformer Upgrade, 127567
480V Transformer Upgrade, 127568
AWB
Terminal
Wire Label
W1
AWB-W1
W2
AWB-W2
W3
AWB-W3
W4
AWB-W4
Main Power
Switch Terminal
Wire Label
4T2
P1
6T3
P2
N
P3
WLD
J2
J7
H
G
Ref. Part
Description
Qty.
1
113802
SCREW, hex hd, flanged
3
2
16C252 GROMMET, air fitting
1
3
16X916 BUSHING, cable
1
4
TRANSFORMER, assembly
1
24V015 480V (Kit 127568)
24V018 400V (Kit 127567)
WLD
1
3
2
4
1