Maintenance
12
334627K
Maintenance
Daily:
Clean hot melt from the exterior of the applicator.
Weekly:
Inspect the applicator, fluid lines, cordset, and solenoid
cable for wear or damage. See
Repair
for
instructions.
Replace Inlet Filter
1.
Disable the applicator. See
Before Beginning
Repair
on page
2.
Remove the dirty filter (C) from the manifold (D).
3.
Apply a thin coating of high-temperature lubricant to
the seals on the filter (C) and install it in the manifold
(D). Torque to 30 in-lb (3.4 N•m) using a 5/32 in (4
mm) Allen wrench.
Filter Maintenance Guidelines
These recommendations are service level guidelines.
Actual service levels required in your factory will vary
based on environmental and operating conditions. High
or low volume adhesive usage, as well as adhesives that
contain a powered release agent or are otherwise dusty,
will have an impact on the frequency of filter
maintenance.
To establish a preventative maintenance cycle tailored to
your environment, Graco recommends inspecting filters
every 4 weeks after installation and replacing when
necessary. Document replacement intervals and use
this as your preventative maintenance schedule moving
forward.
Material inside the applicator can be near setpoint
temperature. Wear protective clothing to avoid severe
burns.
NOTICE
Remove the filter when the applicator is hot. If the
applicator is cold, the adhesive will be hard and the
filter may be difficult to remove or damaged.
F
IG
. 10
WLD
&
&
'
'
Environment Classification
Clean
Moderate
Dusty
Manifold
Filter
Replace filter
every
six
months
Replace filter
every
four
months
Replace filter
every
two
months
Содержание InvisiPac GM100 Plug-Free