Operation
Operation
Operation
Operation
Operation
Operation Overview
Overview
Overview
1.
Plug in the system. The system
powers up and enters Off mode. See
Connect the Power Supply, page 23
2.
Verify that the fluid supply and air supply are
connected. Press the Power button
.
The system enters Standby mode.
3.
Prime the system. Use the control interface
to change the mode to Prime mode. See
. Trigger the gun until
your material dispenses from the gun.
4.
Use the control interface to set the air and fluid
pressure. See
5.
Use the control interface to change the mode
to Spray mode. The system begins to fill. See
.
6.
Begin to spray.
Note
The system automatically refills when
the gun trigger is released and the fluid
level is below the Start Fill setting.
For information about the Start Fill setting, see
Pump Screen 1: Pump Volume, page 58
.
Fluid
Fluid
Fluid Voltage
Voltage
Voltage Discharge
Discharge
Discharge and
and
and
Grounding
Grounding
Grounding Procedure
Procedure
Procedure
The fluid supply is charged with high voltage until
the voltage is discharged. Contact with the charged
components of the voltage isolation system or
spray gun electrode will cause an electric shock.
To avoid an electric shock, do not alter or bypass
the door switch interlock and follow the Fluid
Fluid
Fluid
Voltage
Voltage
Voltage Discharge
Discharge
Discharge and
and
and Grounding
Grounding
Grounding Procedure:
Procedure:
Procedure:
• Whenever you are instructed to discharge the
voltage
• Before cleaning, flushing, or servicing the system
equipment
• Before approaching the front of the gun
• Before opening the isolation cabinet
1.
Release the gun trigger and turn off electrostatics
by turning the ES ON/OFF valve on the back of
the handle to the OFF position.
2.
Engage the trigger lock.
3A7370C