308–507
14
PERFORMANCE CHART
10:1 PRESIDENT
PUMP DELIVERY
PSI
GPM
CFM
50
40
30
20
10
0
2.0
1.6
1.2
.8
.4
0
80
70
60
50
40
30
20
10
0
BAR
Pumps may be operated continuously to shaded area.
f/MIN
M
3
/MIN
PUMP OUTLET PRES
SURE
AIR CONSUMPTION
Outlet Pressure
At 100 Lbs. Air Pressure
Outlet Pressure
At 70 Lbs. Air Pressure
Outlet Pressure
At 40 Lbs. Air Pressure
Air Consumption
At 100 Lbs. Air Pressure
Air Consumption
At 70 Lbs. Air Pressure
Air Consumption
At 40 Lbs. Air Pressure
LEGEND
0
5
10
15
20
5:1 MONARK
PUMP DELIVERY
PSI
GPM
CFM
0
5
10
15
20
25
20
15
10
5
0
0.4
0.3
0.2
0.1
0
16
14
12
10
8
6
4
2
0
BAR
Pumps may be operated continuously to shaded area.
f/MIN
M
3
/MIN
PUMP OUTLET PRES
SURE
AIR CONSUMPTION
Outlet Pressure
At 100 Lbs. Air Pressure
Outlet Pressure
At 70 Lbs. Air Pressure
Outlet Pressure
At 40 Lbs. Air Pressure
Air Consumption
At 100 Lbs. Air Pressure
Air Consumption
At 70 Lbs. Air Pressure
Air Consumption
At 40 Lbs. Air Pressure