background image

10

307010

Service

WARNING

To reduce the risk of serious injury,
whenever you are instructed to relieve
pressure, follow the 

Pressure Relief

Procedure

 on page 4.

SKIN INJECTION HAZARD

Gun Repair 

(See Fig. 6)

NOTE: 

Repair kit 208328 is available for the needle

packings. Use all the parts in the kit for the best re-
sults.

1.

Relieve the pressure

. Disconnect the hose.

Remove the tip guard (9) or nozzle extension.

2.

Unscrew the seat housing (18) and valve seat (8*)
from the gun body.

3.

Using the wrench (3), loosen the packing nut (14).
Then use the wrench (3) to unscrew the needle
(10) from the adjusting nut.

4.

Pull back the trigger (27) and remove the packing
nut (14) and two glands (11*, 13*), four packings
(12*) and locknut (4).

5.

Clean and inspect all parts. Replace worn or
damaged parts as needed. If using a repair kit, use
all the parts in the kit during reassembly.

6.

Lubricate the needle and slide it into the front of
the gun body (2).

7.

Lubricate the new packings and glands. One at a
time, place these parts on the needle; the male
gland (11*), four v-packings (12*) with the lips of
the v-packings facing the front of the gun, and the
female gland (13*).

8.

Screw the packing nut (14) into the center of the
gun body. Screw the locknut (4) onto the needle.

9.

Be sure the spring (16) is in the gun body at the
rear of the center opening. Then, install the adjust-
ing nut (7). Using the wrench (3), insert through
the front of the gun, screw the needle (10) into the
adjusting nut until its end is flush with the valve
body.

10. Press the new valve seat (8*) into the body. Screw

on the seat housing.

11. Adjust the needle before operating the gun. See

Needle Adjustment

 on page 9.

12. Be sure the tip guard and trigger guard are

installed before using the gun.

Fig. 6

8104

8123

3

9

18

*8

10

2

*11

*12

13*

14

4

7

16

Safety On

1.25in. (3.18 mm)

Free Travel

Содержание Hydra-Clean 208008

Страница 1: ...NLESS STEEL Hydra Cleanr Spray Gun 1000 psi 6 9 MPa 69 bar Maximum Working Pressure Model 208008 Series D Spray tip not included purchase separately See page 12 for Tip Selection Chart 307010L Importa...

Страница 2: ...he maximum working pressure of the lowest rated system component This equip ment has a 1000 psi 6 9 MPa 69 bar maximum fluid working pressure D Route the hoses away from the traffic areas sharp edges...

Страница 3: ...onents can inject fluid into your body and cause an extremely serious injury including the need for amputation Splashing fluid in the eyes or on the skin can also cause a serious injury D Fluid inject...

Страница 4: ...y relieved after following the steps above very slowly loosen the tip guard retaining nut or hose end coupling to relieve pressure gradually then loosen completely Now clear the tip or hose Grounding...

Страница 5: ...this valve and the pump after the air regulator is shut off Trapped air can cause the pump to cycle unexpectedly 2 The fluid drain valve assists in relieving fluid pressure in the displacement pump ho...

Страница 6: ...ds are available at no charge from Graco Inc 1 Start the pump Adjust the fluid pressure so the spray is completely atomized Always use the lowest pressure necessary to get the desired results Higher p...

Страница 7: ...peration and at the end of the work day Always relieve the pressure and use a solvent soaked brush to clean the spray tip and to keep fluid buildup from drying and clogging the spray tip If the spray...

Страница 8: ...e 10 or valve seat 8 may need to be replaced See Gun Repair on page 10 If the gun leaks at the packing nut 14 check the tightness of the packing nut Remove the tip guard or nozzle extension Insert a 0...

Страница 9: ...e sure the trigger safety latch makes the gun inoperative when engaged Improper adjustment may allow the gun to be triggered even with the trigger safety latch engaged resulting in serious injury incl...

Страница 10: ...use all the parts in the kit during reassembly 6 Lubricate the needle and slide it into the front of the gun body 2 7 Lubricate the new packings and glands One at a time place these parts on the needl...

Страница 11: ...307010 11 Parts 8103 2 10 18 8 9 3 5 5 19 21 25 23 24 22 26 17 7 16 6 31 30 1 4 14 13 12 11 27 29 28 3 8 npt f 1 4 npt f...

Страница 12: ...ression 1 29 175017 LATCH trigger safety 1 30 175020 PLATE warning 1 31 102299 RIVET blind 2 32 172479 TAG warning not shown 1 33 179960 CARD warning not shown 1 Included in Repair Kit 208238 Included...

Страница 13: ...10 13 Technical Data Maximum Working Pressure 1000 psi 6 9 MPa 69 bar Wetted Parts Stainless Steel PTFE Brass Height 8 25 in 209 6 mm Length 6 75 in 171 5 mm Weight 1 25 lb 0 57 kg Inlet 3 8 npt f swi...

Страница 14: ...f warranty shall be as set forth above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or property o...

Отзывы: