Installation
Installation
Installation
Location
Location
Location
Sit the proportioner on a flat floor surface.
Connect
Connect
Connect the
the
the Fluid
Fluid
Fluid Supply
Supply
Supply Lines
Lines
Lines
1.
Connect the grounded fluid hoses to the pump
inlet fittings (P, R). If the unit will be pressure
fed from separate supply units, install a fluid
pressure gauge at each inlet.
Note
The pressurized fluid supplies must
not exceed 1/4 of the operating fluid
pressure of the pump. Pressure above
that level will feed right through the pump
and improper rationing will result.
Connect
Connect
Connect the
the
the Fluid
Fluid
Fluid Output
Output
Output Lines
Lines
Lines
1.
Connect electronically conductive fluid hoses to
the pump outlet fittings. Tighten all of the fittings.
Figure 1
Key:
Key:
Key:
A
Bleed Type Main Air Valve
B
Air Regulator
C
Pressure Relief Valve
D
Mix Manifold
E
Air Supply Line
F
Air Line Filter
G
Air Shutoff Valve
H
Air Line Lubricator
J
Base Supply Pump
K
Catalyst Supply Pressure Pot
L
Solvent Supply Pump
M
Mix Manifold Flush Inlet
N
Static Mixer
P
Primary Pump Inlet (Base)
R
Secondary Pump Inlet (Catalyst)
S
Ratio Adjustment Screw
T
Spray Gun
U
Ratio Indicator Plate
V
Ratio Indicator Pin
3A3092A
7