Installation
10
310622C
Air Exhaust Ventilation
The air exhaust port is 3/4 npt(f). Do not restrict the air
exhaust port. Excessive exhaust restriction can cause
erratic pump operation.
To provide a remote exhaust:
1.
Remove the muffler (P) from the pump air exhaust
port.
2.
Install a grounded air exhaust hose (T) and connect
the muffler (P) to the other end of the hose. The
minimum size for the air exhaust hose is 3/4 in. (19
mm) ID. If a hose longer than 15 ft. (4.57 m) is
required, use a larger diameter hose. Avoid sharp
bends or kinks in the hose.
3.
Place a container (U) at the end of the air exhaust
line to catch fluid in case a diaphragm ruptures. See
F
IG
. 4.
F
IG
. 4 Venting Exhaust Air
WARNING
Read the
warnings on
page 5 before operating this pump.
Be sure the system is properly ventilated for your type
of installation. You must vent the exhaust to a safe
place, away from people, animals, food handling
areas, and all sources of ignition when pumping flam-
mable or hazardous fluids.
Diaphragm failure can cause the fluid being pumped
to exhaust with the air. Place an appropriate container
at the end of the air exhaust line to catch the fluid. See
F
IG
. 4.
Key:
A
Air supply line
B
Bleed-type master air valve
(required for pump)
C
Air regulator
D
Air line quick disconnect
E
Master air valve (for accessories)
F
Air line filter
P
Muffler
T
Grounded air exhaust hose
U
Container for remote air exhaust