background image

Ordering Information

Ordering

Ordering

Ordering Information

Information

Information

To

To

To Find

Find

Find Your

Your

Your Nearest

Nearest

Nearest Distributor

Distributor

Distributor

1.

Visit

www.graco.com

.

2.

Click on Where

Where

Where to

to

to Buy

Buy

Buy and use the Distributor

Distributor

Distributor

Locator.

Locator.

Locator.

To

To

To Specify

Specify

Specify the

the

the Configuration

Configuration

Configuration of

of

of a

a

a New

New

New

Pump

Pump

Pump

Please

Please

Please call

call

call your

your

your distributor.

distributor.

distributor.

OR

OR

OR

Use the

Online

Online

Online Husky

Husky

Husky Selector

Selector

Selector Tool

Tool

Tool

on the Process

Process

Process

Equipment

Equipment

Equipment page at

www.graco.com

www.graco.com

www.graco.com

...

To

To

To Order

Order

Order Replacement

Replacement

Replacement Parts

Parts

Parts

Please

Please

Please call

call

call your

your

your distributor.

distributor.

distributor.

Distributor

Distributor

Distributor Note

Note

Note

1.

To find part numbers for new pumps or kits, use
the

Online

Online

Online Husky

Husky

Husky Selector

Selector

Selector Tool

Tool

Tool

.

2.

To find part numbers for replacement parts:

a.

Use the configuration number from the ID
plate on the pump. If you only have the
Graco 6–digit part number, use the selector
tool to find the corresponding configuration
number.

b.

Use the Configuration Number Matrix on the
next page to understand which parts are
described by each digit.

c.

Use

Use

Use the

the

the Repair/Parts

Repair/Parts

Repair/Parts Manual

Manual

Manual 3A2889.

3A2889.

3A2889. Refer

to the main Parts illustration and to the
Parts/Kits Quick Reference. Follow the page
references on these two pages for further
ordering information, as needed.

3.

Please call Graco Customer Service to order.

Related

Related

Related Manuals

Manuals

Manuals

Manual

Manual

Manual
Number

Number

Number

Title

Title

Title

3A2889

Husky 15120 Air-Operated Diaphragm
Pump, Repair/Parts

6

3A2888C

Tel:  866-777-6060 
Fax: 866-777-6383

Springer Pumps, LLC

Website: www.springerpumps.com 

Int'l: +001 267 404 2910

Содержание Husky 15120

Страница 1: ...Not Not Not for for for use use use in in in European European European explosive explosive explosive atmosphere atmosphere atmosphere locations locations locations Important Important Important Safet...

Страница 2: ...12 Flange Connections 13 Operation 14 Pressure Relief Procedure 14 Tighten Fasteners 14 Flush the Pump Before First Use 14 Start and Adjust the Pump 14 Pump Shutdown 14 Maintenance 15 Maintenance Sch...

Страница 3: ...es Hold gun firmly to side of grounded pail when triggering into pail Do not use pail liners unless they are antistatic or conductive Stop Stop Stop operation operation operation immediately immediate...

Страница 4: ...r the environment in which you are using it Use equipment only for its intended purpose Call your distributor for information Route hoses and cables away from traffic areas sharp edges moving parts an...

Страница 5: ...ZARD HAZARD Equipment surfaces and fluid that s heated can become very hot during operation To avoid severe burns Do not touch hot fluid or equipment PERSONAL PERSONAL PERSONAL PROTECTIVE PROTECTIVE P...

Страница 6: ...r Distributor Distributor Distributor Note Note Note 1 To find part numbers for new pumps or kits use the Online Online Online Husky Husky Husky Selector Selector Selector Tool Tool Tool 2 To find par...

Страница 7: ...Material Material Material For For For Use Use Use With With With Fluid Fluid Fluid Covers Covers Covers and and and Manifolds Manifolds Manifolds 15120 15120 15120 P P P Polypropy lene P P P Pneumati...

Страница 8: ...hat fittings add friction length to the piping Reduce the number of fittings to reduce the friction length c Increase the size of the suction piping NOTE NOTE NOTE Be sure the inlet fluid pressure doe...

Страница 9: ...quired for your pump installation K Air outlet port and muffler C Air filter regulator assembly L Fluid inlet port D Master air valve to isolate the filter regulator for service M Fluid outlet port E...

Страница 10: ...shing Follow local code Use only conductive metal pails placed on a grounded surface Do not place the pail on a nonconductive surface such as paper or cardboard which interrupts grounding continuity C...

Страница 11: ...the muffler to the other end of the hose The minimum size for the air exhaust hose is 1 in 26 mm ID If a hose longer than 15 ft 4 57 m is required use a larger diameter hose Avoid sharp bends or kinks...

Страница 12: ...a 0 21 0 34 bar should be adequate for most materials 3 For maximum suction lift wet and dry see Technical Data page 22 For best results always install the pump as close as possible to the material so...

Страница 13: ...s Be sure to lubricate the threads of the bolts and torque to 10 15 ft lb 14 20 N m Follow the bolt tightening sequence and do do do not not not over torque over torque over torque KEY KEY KEY L 1 5 i...

Страница 14: ...ounded See Ground The System page 10 2 Check fittings to be sure they are tight Use a compatible liquid thread sealant on male threads Tighten fluid inlet and outlet fittings securely 3 Place the suct...

Страница 15: ...steners Tighten or retorque as necessary Although pump use varies a general guideline is to retorque fasteners every two months See Torque Instructions page 16 Flushing Flushing Flushing and and and S...

Страница 16: ...king in a crisscross pattern to specified torque 3 Repeat for manifolds Fluid Fluid Fluid cover cover cover and and and manifold manifold manifold fasteners fasteners fasteners 190 to 220 in lb 21 to...

Страница 17: ...i 0 48 MPa 4 8 bar D D D 40 psi 0 28 MPa 2 8 bar Air Air Air Consumption Consumption Consumption Approximate Approximate Approximate Cycles Cycles Cycles per per per Minute Minute Minute How How How t...

Страница 18: ...si 0 28 MPa 2 8 bar Air Air Air Consumption Consumption Consumption Approximate Approximate Approximate Cycles Cycles Cycles per per per Minute Minute Minute How How How to to to Read Read Read the th...

Страница 19: ...bar Air Air Air Consumption Consumption Consumption Approximate Approximate Approximate Cycles Cycles Cycles per per per Minute Minute Minute How How How to to to Read Read Read the the the Charts Ch...

Страница 20: ...ylene or or or PVDF PVDF PVDF Pumps Pumps Pumps Ref Ref Ref Inches Inches Inches Centimeters Centimeters Centimeters A A A 20 6 52 3 B B B 23 8 60 4 C C C 26 8 68 1 D D D 3 2 8 1 E E E 9 9 25 1 F F F...

Страница 21: ...Pumps Pumps Pumps Ref Ref Ref Inches Inches Inches Centimeters Centimeters Centimeters A A A 20 6 52 3 B B B 23 8 60 4 C C C 26 8 68 1 D D D 3 2 8 1 E E E 9 9 25 1 F F F 21 0 53 3 Ref Ref Ref Inches I...

Страница 22: ...0 gpm 1 2 m3 min at 0 48 MPa 4 8 bar 227 lpm Maximum Air Consumption 85 scfm 2 4 m3 min Noise Noise Noise dBa dBa dBa Sound power measured per ISO 9614 2 Sound pressure was tested 3 28 ft 1 m from equ...

Страница 23: ...e or or or PVDF PVDF PVDF Non wetted external parts stainless steel polypropylene Fluid Fluid Fluid Temperature Temperature Temperature Range Range Range US US US Metric Metric Metric Diaphragm Ball S...

Страница 24: ...AND AND AND DISCLAIMS DISCLAIMS DISCLAIMS ALL ALL ALL IMPLIED IMPLIED IMPLIED WARRANTIES WARRANTIES WARRANTIES OF OF OF MERCHANTABILITY MERCHANTABILITY MERCHANTABILITY AND AND AND FITNESS FITNESS FIT...

Отзывы: