22
308443
Service
Lips face out of housing (1).
Cutaway View, with Diaphragms in Place
Cutaway View, with Diaphragms Removed
Rounded side faces diaphragm (401).
Air Side must face center housing (1).
Grease.
Apply medium-strength (blue) Loctite® or equivalent.
Torque to 20 to 25 ft-lb (27to 34 N-m) at 100 rpm
maximum.
Used on pumps with PTFE diaphragms only.
4
24
2
104
3
401*
6
403*
5
105
4
24
1
3
5
6
4
3
2
1
105
19
402*
1
1
403*
401*
104
24
1
5
4
2
3
3 6
Fig. 13