Installation
Dust and Foreign Matter
Avoid having dust or foreign matter enter the flow meter
by taking the following precautions:
•
Thoroughly flush the fluid supply lines before install-
ing the flow meter.
•
When installing fittings, make sure that no sealing
tape overlaps into the inside of the pipe.
•
Install a 30 mesh fluid filter upstream of the flow
meter.
•
The flow meter was calibrated in oil. Flush the meter
with a compatible solvent prior to use.
Installing the Flow Meter
•
Flow volume can only be measured at the location
where the flow meter is installed.
•
Do not use more than 200 ft. (61 m) of cable.
•
Refer to F
IG
. 1 to locate and install the flow meter,
connectors, and fluid shutoff valves. Install a check
valve to prevent backflow. The arrows on the flow
meter and check valve show the direction of fluid
flow.
•
The shutoff valves allow you to isolate the meter for
service.
•
Refer to the
Technical Data
and
Dimensional
Drawings
for dimension, inlet/outlet size, tempera-
ture and other specifications.
CAUTION
The use of PTFE tape or pipe seal on fluid fittings
upstream of this meter should be avoided if possible.
Contaminants from sealing material may damage the
meter.
F
IG
. 1
Fluid Shutoff Valve
on outlet side
Fluid Line
Flow Meter
Fluid Filter
Fluid Shutoff Valve
on inlet side
Electronic Sensor Device
Cable
Flow