Setup
30
3A2175Z
Setup
Perform this setup procedure to secure all necessary
machine connections for machine operation.
1. Locate HFR.
a. Locate HFR on a level surface. See
for space requirements.
b. Anchor the HFR to the floor (suggested
anchors: McMaster Carr anchor, 92403A400).
See
, page
, for bolt locations.
c. Do not expose HFR to rain.
2. Electrical requirements. See
on page 4 for
detailed electrical requirements information.
3. Connect electrical cord.
NOTE:
page
.
NOTE:
Power cord is not supplied. See the following
table.
† Residual Current Device (RCD) must be rated at
300 mA if installed.
Electrical Cord Wires by Model
230V, 1 phase:
L1, L2, GND
400V, 3 phase:
L1, L2, L3, N, GND
Use 5/32 or 4 mm hex allen wrench to connect the two
or three power leads to L1, L2, and L3, as applicable.
Connect green to ground (GND).
Electrical Cord Wires by Model
230V, 1phase:
L1, L2, (L3 - No Connection), GND
400V, 3 phase:
L1, L2, L3, N, GND
NOTICE
To avoid machine damage and personal injury,
ensure the machine is securely strapped to the pal
-
let to prevent tipping before lifting.
Installing this equipment requires access to parts
which may cause electric shock or other serious
injury if work is not performed properly. Have a quali
-
fied electrician connect power and ground to main
power switch terminals, see step
in this setup pro
-
cedure. All electrical wiring must be done by a quali
-
fied electrician and comply with all local codes and
regulations.
Table 1: Power Cord Requirements
Model
Cord Requirements
AWG (mm
2
)
230V, 1 phase
6 (13.3), 2 wire + ground
400V, 3 phase
6 (13.3), 4 wire + ground †
F
IG
. 13: 230V, 1 phase shown
L1 L2 L3