Graco Gusmer Power-Lock 256549A Скачать руководство пользователя страница 17

Operation

309572S

17

Operation

1. Connect air hose (C) to main air supply if 

equipped.

2. Connect electrical connectors (D) to con-

nector from fluid manifold (M) or accessory 
control box. See Connect Heated Hoses
page 10. Connect hose cable (F) to cable 
from proportioner fluid manifold (M) or 
accessory control box. Wrap connections 
with electrical tape.

3. Connect to spray gun. See gun manual.

4. Connect whip air hose to gun air inlet if 

equipped. See gun manual.

5. Follow setup, startup, and operation proce-

dures in proportioner manual.

Fluid Temperature Sensor 
(FTS) Calibration

1. Before turning on the unit, ensure all hoses 

and cables are properly connected. To 
ensure that the FTS in the hose is at the 
same temperature as the heaters, keep 
heat off and store the hose FTS near the 
machine for several minutes.

2. While holding down the temperature unit 

button (Fahrenheit - “F” or Celsius - “C”) 
turn the proportioner main power ON.

3. Hold the temperature unit button until tem-

perature is shown on the display. The fluid 
temperature sensor is now correctly cali-
brated.

Maintenance

1. Before disconnecting or repairing hoses, 

relieve all fluid pressure and shut off electri-
cal power to proportioner. See proportioner 
operation manual.

2. Be sure fluid is cool before disconnecting 

hoses.

WARNING

Read warnings, pages 6 and 7.

Do not operate a coiled hose. A coiled hose 
creates uneven heat buildup which can result 
in hose rupture and cause serious injury, 
including fluid injection.

Maximum hose operating temperature is 
180°F (82°C). If using hose without an FTS, 
measure hose temperature to ensure it does 
not exceed 180°F (82°C).

Hose must be properly supported to avoid 
excessive strain due to weight, bending, 
sharp edges, or stress caused by running 
over a roof edge.

F

IG

. 14

M

F

C

D

T

ti9878A

Calibrate the FTS ONLY at initial startup 
(the first time the unit is operated) and 
any time the hose length changes.

WARNING

Read warnings, pages 6 and 7.

Содержание Gusmer Power-Lock 256549A

Страница 1: ...tmospheres See page 3 for Maximum Fluid Working Pressure 130 psi 0 9 MPa 9 bar Maximum Air Working Pressure 180 F 82 C Maximum Hose Operating Temperature Important Safety instructions Read all warning...

Страница 2: ...17 Parts 18 Using 261669 Fluid Temperature Sensor JIC to JIC fittings 18 Using 261670 Fluid Temperature Sensor JIC to NPT fittings 19 15F144 Hose Wire Jumper 21 Technical Data 23 Accessories 23 Scuff...

Страница 3: ...TS cable and scuff guard 3 8 10 50 15 2 5 5 6 6 2000 13 8 138 246052 F With FTS cable no scuff guard 1 4 6 50 15 2 5 5 6 6 3500 24 1 241 246053 F With FTS cable no scuff guard 3 8 10 50 15 2 5 5 6 6 3...

Страница 4: ...47 8 8 10 10 2000 13 8 138 50 15 2 1 4 6 No FTS cable no scuff guard 1225B PL 246074 5 5 6 6 2000 13 8 138 50 15 2 3 8 10 No FTS cable no scuff guard 1200B PL 246075 5 5 6 6 2000 13 8 138 50 15 2 1 2...

Страница 5: ...PL 246063 8 8 10 10 2000 13 8 138 50 15 2 1 2 13 Single hose B RES side 5226C 50 PL 246064 8 8 10 10 2000 13 8 138 25 7 6 1 4 6 Single hose A ISO side 1265A PL 246065 5 5 6 6 2000 13 8 138 25 7 6 1 4...

Страница 6: ...en all fluid connections before operating the equipment Check hoses tubes and couplings daily Replace worn or damaged parts immediately High pressure hose cannot be recoupled replace the entire hose F...

Страница 7: ...with all applicable safety regulations Burn Hazard This equipment is used with heated fluid which can cause equipment surfaces to become very hot To avoid severe burns Do not touch hot fluid or equip...

Страница 8: ...re Taps Transformer tap wire connections vary depending on proportioner and length of heated hose See proportioner operation man ual for further information Some models are automatic and have no user...

Страница 9: ...1 2 Tighten fittings to A and B component hoses Ensure hose remains flat after fit tings are tightened Loosen and retighten fittings as necessary to eliminate any torque on hoses This will help achie...

Страница 10: ...the correct length See Strip Length Gauge for correct length WARNING Read warnings pages 6 and 7 FIG 2 FIG 3 Do not connect the main air supply to the air hose at this time Common insulated heated ho...

Страница 11: ...t See FIG 8 b Thread in setscrew and use hex wrench to torque setscrew to 60 in lbs 6 78 N m c Insert remaining wire from pair into con nector ensure proper insertion depth Thread setscrew and torque...

Страница 12: ...of wire on each side of con nector is wrapped 6 Connect cables F Slide insulator sleeves over connection Leave slack G in cables as stress relief to prevent cable failure 7 Repeat for additional hose...

Страница 13: ...air hose C to whip air hose L 7 Connect hose assembly cable F to FTS cable R Slide insulator sleeves S over connection Leave slack G in cables as stress relief to prevent cable failure 8 See Check Hos...

Страница 14: ...uctions 5 Connect hose assembly cable F to FTS cable R Slide insulator sleeves S over connection Leave slack G in cables as stress relief to prevent cable failure 6 See Check Hoses for Leaks page 15 C...

Страница 15: ...ee proportioner manual for priming instructions After all lines are free of air check for leaks If there are leaks relieve pressure as instructed in proportioner manual Tighten connections then pressu...

Страница 16: ...ap all electrical connections and cable connections with electrical tape to protect them from pulling apart and abra sion 3 Install protective cover see Accessories page 23 or wrap hose bundle with du...

Страница 17: ...F or Celsius C turn the proportioner main power ON 3 Hold the temperature unit button until tem perature is shown on the display The fluid temperature sensor is now correctly cali brated Maintenance...

Страница 18: ...5C624 HOSE air 25 ft 7 6 m 1 4 15B296 CABLE FTS 50 ft 15 2 m 1 15C626 CABLE FTS 25 ft 7 6 m 1 5 261669 FLUID TEMPERATURE SENSOR includes items 5a 5d 1 5a 117455 NIPPLE 1 4 npt m x 5 JIC m 1 5b 117595...

Страница 19: ...t A ISO 1 2 chart 2 page 20 HOSE component B RES 1 4 15B296 CABLE FTS 50 ft 15 2 m 1 15C626 CABLE FTS 25 ft 7 6 m 1 5 261670 FLUID TEMPERATURE SENSOR includes items 5a 5d 1 5a 156823 SWIVEL 1 4 npt m...

Страница 20: ...in mm Length ft m Maximum Fluid Pressure psi MPa bar 246059 1 4 6 50 15 2 2000 13 8 138 246061 3 8 10 50 15 2 2000 13 8 138 246063 1 2 13 50 15 2 2000 13 8 138 246065 1 4 6 25 7 6 2000 13 8 138 246094...

Страница 21: ...ed Hoses page 10 6 Install one Lock connector 100a between wires see page 10 Ref Part Description Qty 100 15F144 JUMPER hose wire includes two 117789 electrical connec tors 50 ft 15 2 m long 1 101 cha...

Страница 22: ...aps using the follow ing table Transformer tap wire connections vary depending on length of heated hose See proportioner operation manual for fur ther information Verify that tap wire con nections are...

Страница 23: ...eel Total Heating Load 2 hoses 1 4 diameter 11 watts foot 36 watts meter 3 8 diameter 13 watts foot 43 watts meter 1 2 diameter 15 watts foot 49 watts meter Part Description 256735 7 ft 2 1 m braided...

Страница 24: ...in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARR...

Отзывы: