background image

309227         3

WARNING

FIRE, EXPLOSION, AND ELECTRIC SHOCK HAZARD

Improper grounding, poor air ventilation, open flames, or sparks can cause a hazardous condition and
result in fire, explosion, or electric shock, which can result in serious injury.

Ground the equipment and the object being sprayed. See 

Grounding 

on page 7.

Provide fresh air ventilation to avoid the buildup of flammable fumes from solvent or the fluid being
sprayed. Never operate the Gun Flush Box unless ventilation fans are operating.

Eliminate all ignition sources such as pilot lights, cigarettes and plastic drop cloths (static arc haz-
ard). Do not plug or unplug power cords or turn lights on or off in the spray area.

Keep the spray area free of debris, including solvent, rags, and gasoline.

Do not operate a gasoline engine in the spray area.

If there is any static sparking while using the equipment, 

stop spraying immediately

. Identify and

correct the problem.

Electrostatic Gun Safety

Do not flush the system with the gun electrostatics turned on.

Interlock the gun turbine air supply to prevent operation of the power supply during flushing.

Do not turn on the gun electrostatics until all solvent is removed from the system.

When cleaning, flushing, or purging electrostatic equipment, use solvents that comply with your
local regulations. 

For countries following the U.S. National Fire Protection Association (NFPA) 33

requirements,

 use solvents with a flash point higher than 100

 F (38

 

C) or a solvent normally

used in spray operations. 

For European Countries complying with EN 50053,

 use solvents with a

flash point as high as possible and higher than the ambient temperatures.

PRESSURIZED EQUIPMENT HAZARD

Spray from the gun, hose leaks, or ruptured components can splash fluid in the eyes or on the skin
and cause serious injury.

Do not bypass the Gun Flush Box interlock sensors. They prevent the Gun Flush Box from operat-
ing unless the gun is in position and the door of the box is locked.

Connect an interlock to prevent atomizing air from turning on during flushing.

Do not stop or deflect fluid leaks with your hand, body, glove, or rag.

Tighten all the fluid connections before operating the equipment.

Check the hoses, tubes, and couplings daily. Replace worn, damaged, or loose parts immediately.
Permanently coupled hoses cannot be repaired; replace the entire hose.

Содержание Gun Flush Box 244105

Страница 1: ...APOLIS MN 55440 1441 Copyright 2000 Graco Inc is registered to I S EN ISO 9001 Gun Flush Boxt Module 100 psi 0 7 MPa 7 bar Maximum Air Inlet Pressure Part No 244105 U S PATENT NO 6 554 204 309227D Rea...

Страница 2: ...nting 6 Enclosed Waste Container 7 Grounding 7 Connect Tubing to the Pneumatic Controls 9 Trigger Height Adjustment 10 Operation 11 PrecisionMix II Controller Operation 11 Operating Checklist 11 Troub...

Страница 3: ...ation of the power supply during flushing Do not turn on the gun electrostatics until all solvent is removed from the system When cleaning flushing or purging electrostatic equipment use solvents that...

Страница 4: ...e traffic areas sharp edges moving parts and hot surfaces Do not expose Graco hoses to temperatures above 180 F 82 C or below 40 F 40 C Use only Graco approved hoses Use fluids or solvents that are co...

Страница 5: ...enclosed waste container The advantages of using the Gun Flush Box instead of conventional flushing methods include Reduced solvent use Reduced VOC volatile organic compounds emis sions Improved oper...

Страница 6: ...supply with the ventilators to prevent the box from operating when ventilating fans are not operating Check and follow all National State and Local codes regarding air exhaust velocity requirements Lo...

Страница 7: ...AZARD To reduce the risk of fire explosion or electric shock the system must be properly grounded Follow the warnings on page 3 Ground the Gun Flush Box and waste container as instructed below Ground...

Страница 8: ...8 309227 Installation Typical Installation of Gun Flush Box in PrecisionMix System Fig 4...

Страница 9: ...ternal pneumatics Fig 5 BOTTOM VIEW 1 Connect a 5 32 4 mm OD tube between the air supply and the P bulkhead Use a clean dry air supply filtered to 10 microns WARNING EQUIPMENT MISUSE HAZARD Do not exc...

Страница 10: ...o the Gun Flush Box See Fig 7 3 Force the cylinder triggers on by connecting air to port C J See Fig 7 Turn on the air to extend both cylinders 4 Loosen both screws L on the side of the box that hold...

Страница 11: ...ostatics P before placing the spray gun in the Gun Flush Box See Fig 9 ____ 3 The system is thoroughly grounded and the operator and all persons entering the spray area are properly grounded See Groun...

Страница 12: ...h Box when it is not in use p Gun switch is not activating Test the switch Replace it if it is dam aged Gun trigger is not open when the Gun Flush Box controller acti Tubing is not installed correctly...

Страница 13: ...patible solvent Clean the inside and out side of the enclosure with a compatible solvent Door Keep hinge holes as clean as possible Grease hinges Cylinders Pull the cylinder rod for ward and coat wit...

Страница 14: ...assembly Selection of correct gun holder required for proper operation 5 27 36 2 TI0576 TI0577b 9 10 1 55 54 14 16 15 42 43 44 20 4 3 11 12 13 6 7 8 6 7 8 6 7 8 55 8 41 26 27 20 19 17 24 23 18 21 22 2...

Страница 15: ...SUPPORT cover 1 29 551794 CYLINDER air 0 568 dia 1 30 551795 NUT hex head 7 16 20 1 31 626504 BUTTON cylinder 1 Ref No Part No Description Qty 32 196708 ARM lever 1 33 551793 CYLINDER air 0 438 dia 1...

Страница 16: ...d are trademarks of their respective owners 244169 Gun Holder Conversion Kit Allows mounting of new gun holder in older style gun flush box Part No 570046 Requires purchase of appropriate gun holder s...

Страница 17: ...t 22 lbs 9 6 kg Height 14 356 mm With door open 21 533 mm Width 7 178 mm Length 11 279 mm Outlet 2 npt f Maximum Air Inlet Pressure 100 psi 0 7 MPa 7 bar Wetted Parts Stainless steel nylon ultra high...

Страница 18: ...set forth above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or property or any other incidental...