Cleanup
310802A
15
5
Hold gun against paint pail.
Take trigger safety OFF.
Turn pressure control up
until motor begins to drive
pump. Trigger gun until
flushing fluid appears.
6
Move gun to flushing pail,
hold gun against pail, trig-
ger gun to thoroughly flush
system.
Release trigger and put
trigger safety ON.
7
Turn prime valve down and
allow flushing fluid to circu-
late for approximately 20
seconds to clean drain
tube.
8
Raise siphon tube above
flushing fluid and run
sprayer for 15 to 30 sec-
onds to drain fluid. Turn
pump valve OFF. Turn
engine OFF.
3$,17
WLD
)/86+
WLD
6(&
WLD
WLD
/&&
PAINT
FLUSH
ti5275a