Setup
22
313855K
Quick System Setup
Pressing CANCEL at any point will move to the previous subsection or the beginning of the previous section
of the Quick System Setup.
Holding CANCEL for 3 second will abort the system setup.
PUMP ON
Defines when a lubrication event ends.
PUMP OFF
Defines when a lubrication event begins.
Low Level
Defines behavior of low level input. Typically used to signal controller when the
lubrication level in the tank is low.
1.
PUMP ON Mode
Use arrows to select mode icon, then press ENTER.
a.
Timer
Enter ON Time in HH:MM:SS by using the LEFT/RIGHT arrows to select digit
and use the UP/DOWN arrows to change time.
b.
Pressure
Enter ON Timeout in HH:MM:SS buy using the LEFT/RIGHT arrows to select
digit and use the UP/DOWN arrows to change time. If pressure is not reached
within this timeout the controller will enter a fault state.
c.
Cycles
Defines the number of cycles needed to finish a lubrication cycle.
i.
Enter ON Timeout in HH:MM:SS by using the LEFT/RIGHT arrows to select digit
and use the UP/DOWN arrows to change value. If cycle count is not reached
within this timeout, the controller will enter a fault state.
ii.
Enter Cycle Count by using LEFT/RIGHT arrow to select digit and use
UP/DOWN arrows to change time.