Troubleshooting
332078C
45
Troubleshooting
Before performing any troubleshooting procedure:
1. Perform
on page 42.
2. Press the Stop Button.
3. Remove air supply.
4. Allow the press equipment to cool.
Calibrate Pressure Transducers
Perform this procedure when the “Actual” Value shown
on the “Calibration” screen has a difference of 100 psi
(7 MPa, 0.7 bar) from the value shown on the analog
pressure gauge.
1. Perform
on page 42.
2. Navigate to the “Calibration” screen.
3. Set the offset to “0” on the transducer being cali-
brated.
4. Type the number displayed in the “Actual” field into
the “Offset” field.