4

MOVING PARTS HAZARD

Moving parts can pinch or amputate your fingers.

D

Keep clear of all moving parts when starting or operating the pump.

D

Before servicing the equipment, follow the

 Pressure Relief Procedure

 on page 10 to prevent the

equipment from starting unexpectedly.

FIRE AND EXPLOSION HAZARD

Improper grounding, poor ventilation, open flames, or sparks can cause a hazardous condition and
result in a fire or explosion and serious injury.

D

Ground the equipment.  Refer to 

Grounding

 below.

D

If there is any static sparking or you feel an electric shock while using this equipment, 

stop

dispensing immediately.

 

 

Do not use the equipment until you identify and correct the problem.

D

Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid
being dispensed.

D

Do not smoke in the dispensing area.

WARNING

WARNING

United States Government safety standards have been adopted under the Occupational Safety and Health Act.

You should consult these standards--particularly General Standards, Part 1910, and Construction Standards,

Part 1926.

Installation

Grounding 

To reduce the risk of static sparking, ground the pump.
Check your local electrical code for detailed grounding
instructions for your area and type of equipment.

D

Pump:

  Use ground wire and clamp as shown in

Fig. 1.

D

Air and fluid hoses:

  Use only electrically conductive

hoses.

D

Air compressor:

  Follow manufacturer’s

recommendations.

D

Dispensing valve: 

 Obtain grounding through

connection to a properly grounded fluid hose and
pump.

D

Fluid supply container: 

 Follow your local code.

D

Object being lubricated: 

 Follow your local code.

D

Any pails used when flushing:

  Use only metal,

grounded pails when flushing. Make firm
metal-to-metal contact between a metal part of the
dispensing valve and the pail. Use the lowest
possible pressure.

D

To maintain grounding continuity when flushing or
relieving pressure,

 always hold a metal part of the

dispensing valve firmly to the side of a 

metal pail

,

and then open the dispensing valve.

Fig. 1

X

W

Y

Z

04630

To ground the pump,

 loosen the grounding lug

locknut (W) and washer

 

(X).  Insert one end of a

12 ga (1.5 mm

@

) minimum ground wire (Y) into

the slot in the lug (Z), and tighten the locknut
securely.  Connect the other end of the wire to a
true earth ground.  See Fig. 1.  To order a
ground wire and clamp, order Part No. 222011.

Содержание FIRE-BALL Series

Страница 1: ... truck mounted 204264 55 gallon closed drum truck mounted S S M M X X X X X X X X X X X 225931 275 gallon obround tank S X X 10 1 Ratio President Pump 1800 psi 120 bar MAXIMUM WORKING PRESSURE Model No Size Type Hose Kit Cover Bung Adapter Sturdi Clamp Hold Down Kit 225782 55 gallon open drum S X X 225786 55 gallon closed drum 206656 55 gallon closed drum truck mounted 222067 55 gallon closed drum...

Страница 2: ...atible with the equipment wetted parts Refer to the Tech nical Data section of all equipment manuals Read the fluid and solvent manufacturer s warn ings D Handle hoses carefully Do not pull on hoses to move equipment D All fluid hoses must have spring guards on both ends The spring guards help protect the hose from kinks or bends at or close to the coupling which can result in hose rupture D Route...

Страница 3: ...o your body and cause extremely serious injury including the need for amputation Fluid splashed in the eyes or on the skin can also cause serious injury D Fluid injected into the skin may look like just a cut but it is a serious injury Get immediate medical attention D Do not point the dispensing valve at anyone or at any part of the body D Do not put your hand or fingers over the end of the dispe...

Страница 4: ...rt 1926 Installation Grounding To reduce the risk of static sparking ground the pump Check your local electrical code for detailed grounding instructions for your area and type of equipment D Pump Use ground wire and clamp as shown in Fig 1 D Air and fluid hoses Use only electrically conductive hoses D Air compressor Follow manufacturer s recommendations D Dispensing valve Obtain grounding through...

Страница 5: ...5 307883 Notes ...

Страница 6: ...ps 1 Remove the original drum cover 2 Mount and fasten the new drum cover 3 Guide the pump riser tube through the mounting gasket Closed Bung Type Drum 1 Loosen the drum cover vent plug and remove the bung cover 2 Install the pump through the bung hole until the pump foot valve is 1 2 in 13 mm off the drum bottom Tighten the bung adapter Air and Fluid Line Accessories Install the accessories in th...

Страница 7: ...d and pressure To order a 300 psi 21 bar maximum working pressure regulator order a Part No below 3 8 in npt 109107 1 2 in npt 104266 D Install an air line filter H to remove harmful dirt and contaminants from your compressed air supply To order a 250 psi 17 5 bar maximum working pressure air filter order a Part No below 3 8 in npt 106148 1 2 in npt 214849 D Install a thermal relief kit on the dis...

Страница 8: ...sufficient room to change drums and a secure mounting platform Drum Mounting 1 Place the drum in the desired location 2 Place the hold down lugs V or drum locators U around the drum base and bolt directly to the truck bed or mounting platform See Fig 5 Open Drum Cover Mounted Pumps 1 Remove the original drum cover 2 Mount the new drum cover and fasten 3 Guide the pump riser tube through the mounti...

Страница 9: ...um Sturdi Clamp Mounted Pumps 1 Remove the adjustable bung adapter from the pump riser tube 2 Screw the bung adapter EE into the bung hole 3 Loosen the wing nuts BB and slide the clamp AA onto the pump riser tube up to the base See Fig 7 4 Holding the clamp onto the pump insert the pump riser tube through the bung adapter and lower the pump until the clamp rests on the edge of the drum See Fig 7 5...

Страница 10: ...lves to all but one pump 2 Open the master air valve from the compressor 3 For the pump that is connected trigger the dispensing valve into a grounded metal waste container making firm metal to metal contact between the container and valve Open the bleed type master air valve and open the pump air regulator slowly just until the pump is running When the pump is primed and all air has been pushed o...

Страница 11: ...11 307883 Notes ...

Страница 12: ...M COVER 1 Model 222086 5 1 Ratio Fire Ball 16 Gallon Open Drum Ref No Part No Description Qty 4 203872 5 1 FIRE BALL PUMP See manual 306518 for parts 1 5 222063 HOSE FITTING KIT See parts list above 1 6 222060 DRUM COVER 1 7 222061 HOLD DOWN KIT See manual 306345 for parts 1 Model 225642 5 1 Ratio Fire Ball 55 Gallon Open Drum Ref No Part No Description Qty 8 203857 5 1 FIRE BALL PUMP See manual 3...

Страница 13: ...io Fire Ball 55 Gallon Closed Drum Ref No Part No Description Qty 17 204254 5 1 FIRE BALL PUMP See manual 306518 for parts 1 12 222063 HOSE FITTING KIT See parts on page 12 1 19 204076 BUNG ADAPTER sealed 1 20 207361 HOLD DOWN KIT See manual 306345 for parts 1 21 204095 STURDI CLAMP 1 13 14 16 15 17 18 20 19 21 01621 01622 Model 225931 5 1 Ratio Fire Ball 275 Gallon Obround Tank Ref No Part No Des...

Страница 14: ...r parts 1 42 222066 HOSE FITTING KIT See parts list above 1 43 207367 DRUM COVER 1 44 207361 HOLD DOWN KIT See manual 306345 for parts 1 Model 222067 10 1 Ratio President 55 Gallon Closed Bung Ref No Part No Description Qty 45 222095 10 1 PRESIDENT PUMP See manual 306726 for parts 1 46 222066 HOSE FITTING KIT See parts list above 1 47 224579 BUNG ADAPTER sealed 1 48 207361 HOLD DOWN KIT See manual...

Страница 15: ...15 307883 Notes ...

Страница 16: ... be made at a reasonable charge which charges may include the costs of parts labor and transportation DISCLAIMERS AND LIMITATIONS The terms of this warranty constitute purchaser s sole and exclusive remedy and are in lieu of any other warranties express or implied including warranty of merchantability or warranty of fitness for a particular purpose and of any non contractual liabilities including ...

Отзывы: