Installation
General Information
NOTE: Reference numbers and letters in parentheses
in the text refer to the callouts in the figures and the
parts drawing.
NOTE: Always use Genuine Graco Parts and Acces-
sories, available from your Graco distributor.
Grounding
WARNING
FIRE AND EXPLOSION HAZARD
Before operating the pump, ground the
system as explained below. Also read
the section
FIRE OR EXPLOSION HAZ-
ARD on page 4.
1.
Pump: use a ground wire and clamp as shown in
Fig. 1. Loosen the grounding lug locknut (W) and
washer (X). Insert one end of a 12 ga (1.5 mm
)
minimum ground wire (Y) into the slot in lug (Z)
and tighten the locknut securely. Connect the other
end of the wire to a true earth ground. Order part
number 222–011 Grounding Clamp and Wire.
2.
Air and fluid hoses: use only electrically conductive
hoses.
3.
Air compressor: follow manufacturer’s recommen-
dations.
4.
Spray gun or dispensing valve: ground through
connection to a properly grounded fluid hose and
pump.
5.
Object being sprayed: follow your local code.
6.
Fluid supply container: follow your local code.
7.
Solvent pails used when flushing: follow your local
code. Use only metal pails, which are conductive,
placed on a grounded surface. Do not place the
pail on a nonconductive surface, such as paper or
cardboard, which interrupts the grounding continu-
ity.
8.
To maintain grounding continuity when flushing or
relieving pressure, hold a metal part of the spray
gun firmly to the side of a grounded
metal pail,
then trigger the gun.
Fig. 1
Y
W
Z
X
06431
Содержание Fire-Ball 992-706 A
Страница 11: ...11 307 759 Notes ...
Страница 17: ...17 307 759 Notes ...
Страница 22: ... Notes ...
Страница 23: ... Notes ...