3
306-523
Installation
Note: Choose a location with sufficient overhead
clearance, and adequate clearance for plumbing when
unit is being raised or lowered.
Note: Numbers and letters in parenthesis refer to
callouts in the Figures and Parts Drawing.
Assemble the Elevator to the Base
(See Fig. 1)
Note: All necessary nuts, screws, and washers are
provided with Base Assy. 204740.
1.
Set three flat washers (B) in place over the mount-
ing holes in the base.
2.
Position the elevator on the washers (B).
3.
Place three flat washers (B) over the holes in the
elevator base casting.
4.
Fasten securely with three screws (A),
lockwashers (C) and nuts (D).
Fig. 1
06384
A
B
C
D
E
G
Assemble the Pump to the Elevator
(See Fig. 2)
1.
Remove the elevator clamp (34) from the elevator
bracket (33).
2.
Center the the pump and inductor plate (8) on the
base (H), straddling the elevator tube (F).
3.
Tighten the screws (19) securing the clamp (34) to
the bracket (33). See the Parts Drawing on
page 6.
4.
Place the unit in the desired location, and use
metal shims to to level the base, if necessary.
5.
Anchor the unit to the floor using the mounting
holes (G) in the base. See Fig 1.
Connect the Hoses
1.
Connect the 1/4 npt(m) end of the fluid hose (27)
between the outlet of the pump and the permanent
supply line.
2.
Connect the 3/8 npt(m) end of the air hose (5) to
the permanent supply.
Fig. 2
06381A
8
33
F
H
37
5
34
27
Model 241032 shown