Software Update
58
3A6165J
Software Update
NOTE:
If burning your own software token, see the ADM
Token Programming manual. See
on
page 2. Otherwise, proceed to
.
17Y711 Software Update
Procedure
NOTE:
A token can be found in the ADM token compart
-
ment.
When software is updated on the ADM the software is
then automatically updated on all connected modules. A
status screen is shown while software is updating to
indicate progress.
1. Turn power disconnect switch (C) to the OFF
position.
2. Remove ADM from bracket.
3. Remove token access panel (BK).
4. Insert and press EFR software upgrade token (TK,
part no. 17Y711) firmly into slot.
NOTE:
There is no preferred orientation of token.
5. Turn the power disconnect switch (C) to the ON
position.
NOTE:
When the ADM display turns on, you may see
the following screens:
6. Remove token (TK).
7. Replace token access panel (BK).
8. Install ADM into bracket.
9. Press
to continue to EFR operation screens.
BK
ADM
TK
NOTICE
A status is shown while software is updating to
indicate progress. To prevent corrupting the software
load, do not remove token until the status screen
disappears.
First:
Software is checking
which modules will take
the available updates.
Second:
Status of the update with
approximate time until
completion.
Third:
Updates are complete.
Icon indicates update
success/failure. See the
following Icon table.
Icon
Description
Update successful.
Update unsuccessful.
Update complete, no changes necessary.
Modules were updated or didn’t require an
update; however, one or more modules need to
be updated manually with a token.