ADM Screen Overview
3A6165J
47
Tank Stand Status Information
NOTE:
The tank stand status information and icons will
only be shown when the tank stand is connected to the
EFR network.
Tanks Status Fill Levels
: These icons display the fill
level of the each of the tanks.
Manual Refill
: Press
or
to initiate a tank
refill. If a tank is filling, pressing either button will abort
the filling operation.
Voltex Dynamic Mix Valve Run
Screen
NOTE:
This screen will only be displayed if the Voltex
Dynamic Mix Valve is connected to the EFR Network.
1.
System State:
Green frame with Active indicated
means the system is ready to run. Amber frame with
System Off indicated means system is off.
2.
Motor RPM Setpoint:
The RPM’s that the motor
will run at. The Motor RPM Setpoint can be locked
requiring a password.
3.
Motor Ramp Up Time:
This changes the amount of
time in milliseconds the motor takes to get to the
RPM setpoint. NOTE: 100ms is the fastest
acceleration and 9000ms is the slowest
acceleration. The goal is to try and prevent breaking
mixers with a slower acceleration. Example: 500ms
= half a second to get to the RPM setpoint of 4400
RPM.
4.
(B) Valve Status:
Icon turns green when the
dispensing system turns on the valve signal. Icon
turns grey when dispensing system is off.
5.
(B) Valve Pressure:
If a pressure transducer kit is
installed, the text will appear on the screen and
display the pressure. There is no error for the
transducer being unplugged.
6.
Manual Motor:
This button allows the motor to be
turned on by the ADM at the RPM setpoint.
7.
Motor Actual RPM:
Shows what speed the motor is
at during the ramp period. It is not direct feedback
from the motor.
8.
Air nucleation valve indicator:
Icon turns green if
air nucleation is enabled and the valve is open. Icon
turns grey when it is off.
9.
Air Purge button:
Will open the air nucleation valve
indefinitely to blow out the material in the mixer.
10.
(A) Valve Pressure:
If a pressure transducer kit is
installed, the text will appear on the screen and
display the pressure. There is no error for the
transducer being unplugged.
11.
(A) Valve Status:
Turns on when the dispensing
system turns on the valve signal.
12.
Edit Mode:
Select to enter or exit the editing mode
for the screen. Icon is grey when in edit mode and
blue when off.
F
IG
. 12
1
12
11
10
9
2
3
4
5
6
7
8