Technical Specifications
Ex45
Ex45
Ex45 e
e
e---Xtreme
Xtreme
Xtreme Sprayers
Sprayers
Sprayers
U.S.
U.S.
U.S.
Metric
Metric
Metric
Maximum fluid working pressure
4500 psi
310 bar, 31.0 MPa
Stroke length
4.75 in.
120 mm
Maximum continuous cycle rate
44 cycles per minute
Tip Size
.021 in.
Weight
295 lb
135 kg
Wetted parts
Carbon Steel, Alloy Steel, 304, 440 and 17–PH Grades
of Stainless Steel, Zinc and Nickel Plating, Ductile Iron,
Tungsten Carbide, PTFE; Leather, Aluminum
Maximum fluid temperature
See Models information in Operation/Repair manual.
Operating temperature range
23° to 120° F
-5° to 50° C
Input voltage
200–240 VAC, single phase, 50/60 Hz
Input power
2.5 kVA
Minimum Recommended generator size
5 kW
Oil capacity
1.0–1.2 quarts
0.9–1.1 liters
Oil specification
Graco part number 16W645 silicone-free ISO
220 synthetic EP gear oil
Inlet / Outlet Sizes
Fluid inlet size
1 in. npt(m) [also includes 1 in. nps(swivel) to
1 in. npt(m) adapter elbow]
Fluid outlet size
1/2 npt(m) [also includes 1/2 npt(f) to 3/8 npt(m) adapter]
Hose Requirements
Minimum pressure
The minimum hose pressure rating should be equal to or
greater than the maximum fluid working pressure of sprayer
Minimum length
50 ft.
15 m
Minimum ID
3/8 in.
10mm
Maximum resistance per ISO 8028
9,100 ohms/ft
30,000 ohms/m
Sound Emissions (per ISO 9614) for Normal Operation (Spraying @ 20 cpm)
Sound Pressure LpA Average
70.2 dBA
Sound Power LwA Total Power
76.7 dBA
Sound Emissions (per ISO 9614) for Maximum Speed (Flushing @ 44 cpm)
Sound Pressure LpA Average
77.4 dBA
Sound Power LwA Total Power
85.1 dBA
3A3164D