Setup
Setup
Setup Screen
Screen
Screen 15
15
15
Use this screen to set up the input scaling (radar level
sensor) for 4–20mA devices and turn on the current
loop (Port 8 and Port 9 of the ADCM).
Figure 51 Setup Screen 15
Setup
Setup
Setup Screen
Screen
Screen 15
15
15 Key
Key
Key
Monitor the back pressure regulator mA
output.
Set the value for P9 (Port 9) between 4
and 20.
Select this box to turn on the 4-20mA
supply. Set the numerical values for the
scaling ceiling for 4-20mA signal.
Current off production tank level. See
Setup
Setup
Setup Screen
Screen
Screen 16
16
16
This screen is for enabling a modbus communications
alarm and disabling the Stop Pump function of the
Cancel key.
Figure 52 Setup Screen 16
Setup
Setup
Setup Screen
Screen
Screen 16
16
16 Key
Key
Key
Select the modbus alarm type:
None
Deviation
Alarm
Select this box to make CAN
communication a deviation that
does not shut down the pump.
Select this box to disable the Stop Pump
function of the Reset/Cancel key.
Enable or disable the backlight and set
the time-out value in minutes.
Setup
Setup
Setup Screen
Screen
Screen 17
17
17
Use this screen to enable or disable the run/stop
switch and auto restart.
Figure 53 Setup Screen 17
Setup
Setup
Setup Screen
Screen
Screen 17
17
17 Key
Key
Key
Enable or disable the run/stop
switch. The default setting is
disabled. See Run/Stop Switch Kit
in
When enabled, this configuration allows
the run/stop switch to pause the pump
while in a profile. When the run/stop
switch is active, the following pop-up
appears:
Disable the remote start function over
modbus.
When enabled along with the run/stop
switch, you must toggle the run/stop
switch when going from profile 0
(stopped) to run before the pump can
start. When the run/stop switch is active,
the following pop-up appears:
Enable or disable auto restart. The
default setting is disabled. If enabled, the
unit resumes operation at the profile that
was set before the unit was turned off.
Enable off production profile mode.
This feature turns profile 4 into the off
production profile. When profile 4 is
active, the fill pump is disabled and the
current primary tank level is recorded. If
the primary tank level drops more than
3%, the system triggers the alarm and
shuts off the pump.
3A3453H
41