Heat Run Screen
When Heat is selected for a pump at the System Setup
screen, a Heat Run screen is available. See
System
Setup Screen
. Use the ADM directional
keypad (BH) to go to the Heat Run screen.
The Ram Heat Run screen is identical to the Tandem
Heat Run screen except for the Menu Bar as shown
below.
NOTE:
The zone must be enabled at the Heat Setup
screen 1 to be displayed on the Heat Run screen. See
Heat Settings
.
The pump heat zones are shown on the left side of the
screen and the zones for the other system components
are shown on the right. The number in the box next to
the pump is the pump number.
For each component, the number outside the left
bracket is the connector number. The number just
inside the left bracket is the zone number.
The temperature reading inside the box is the zone
setpoint/setback temperature. It is the setpoint to
which control is heating the zone when the zone is
turned on. When the system is placed in setback, the
temperature displayed in the box is the setback value.
The temperature units can be changed from °C to °F in
the Advanced Settings screens. See
Advanced Setup
Screen 2
The zone heat symbols on the right side of the screen
correspond to the current type to which the zone is set.
The number to the right of the Zone Heat Symbol is the
zone’s actual temperature. The temperature unit is the
same as the zone setpoint/setback temperature unit.
The zone heat state is the circle with a number inside of
it next to the temperature unit. There are four different
colors used in the indicators for the heat zone.
1. Press the
soft key to turn the heat zones on
and off.
Zone Heat Symbol
Hose
Valve
Manifold
PGM
Flowmeter
Press Regulator
Pump
Platen
Color
Description
Green
Heat zone is at temperature.
Yellow
Heat Zone is in setback.
Yellow to
Green
Heat zone is warming up or heat zone is
heat soaking. It starts as yellow then
progresses clockwise to green as it
warms up. The pump number also
flashes yellow to green during heatsoak.
Green to
Red
Heat zone has a deviation/advisory.
Red
Heat zone has an alarm.
White
Heat zone is turned off.