Setup
333587D
23
Setup
It is important to set up the parameters of your system
before operating the E-Flo iQ system. These are
accessed through the iQ Menu. After starting up the
ADM, press the
key from the Run screen to go to
the iQ Menu screens. Refer to
iQ Menu
on page
System Setup Screen
Press the
soft key at the iQ Menu screen 2 to
access the System Setup screen.
Press the
soft key to enter editing mode.
Use the drop down menu to select the type of system
as either Ram or Tandem.
NOTE:
Changing the system type resets the pumps in
the system.
When you select Ram
, the only action required at this
screen is if the pump has a heat module installed. Press
the
key in the Heat box to configure it for heat.
All other fields are automatically set when the blue
token is inserted on an installed system. The System is
displayed as Ram. The box below the iQ icon next to
the System field indicates that it is an E-Flo iQ system.
The Pump shows as Installed. The Serial Number
should match the serial number printed on the driver ID
tag. As a backup to the driver serial number, the serial
number of the current board will be displayed instead.
The serial number for the control board is also
displayed in the detailed software status screens. See
Advanced Setup Screen 4
.
When you select Tandem
, a field for the second pump
is displayed on the screen showing Uninstalled. Select
Installed from the drop down menu.
To prevent personal injury from pressurized fluid
such as skin injection or splashing fluid, make sure
that all components in your system are rated to the
maximum pressure the system is capable of
attaining. All components must be rated for
maximum pressure even if the pump is operated
below maximum pressure.
NOTICE
To prevent damage to ADM buttons, do not press the
buttons with sharp objects such as pens, plastic
cards, or fingernails.
NOTICE
To prevent damage to components in the system, all
components must be rated to the maximum pressure
the system is capable of attaining.