Installation
6
332515F
External Alarm or Warning Light (Optional)
An external (user supplied) alarm or warning light can
be added to the Low Level Indicator to provide an audi-
ble or visual signal in a low level situation.
1.
Connect the DIN connector on the Low Level Indica-
tor to the (user supplied) alarm device. Connection
is made to PINS 1 and 3 of the DIN, Form “A” Field
Wireable Adapter. See F
IG
. 14.
2.
Connect Dyna-Star pump to main power source.
3.
Start system following pump start up procedure
included in the Dyna-Star HP or HF Pump Manual
provided with your system.
NOTICE
To avoid premature failure and the loss of fluid/low
level indication:
•
Do not exceed the rating of the Low Level Sen-
sor Switch by connecting excessive lights or
audible signals.
•
Level Sensor Switch is rated for a maximum of
32 VDC and 10 Watts. Maximum switch current
is 0.4 AMPS.
F
IG
. 14