background image

Dyna-Star

®

 HP or HF Pump 

Low Level Indicator Kit; Dip 
Stick Kit 

332515F

EN

Provides a visual reference of remaining fluid level in a tank / reservoir used with the 
Dyna-Star HP or HF pump.

 

Low Level Indicators equipped with a user supplied alarm will 

also provide an audible and/or visual notification of a low fluid level. For professional use 
only. 

Low Level Indicator Part No: 77X522

Includes sight glass, electric low level switch and cable. Requires follower plate. Cannot be used with Auto-Fill

®

 Shut Off.

Dip Stick Part No: 77X530 - 90#; 77X531 - 60#

Cannot be used with a follower plate or Auto-Fill Shut Off.

Important Safety Instructions

Read all warnings and instructions in this 
manual and in the Dyna-Star HP or HF Pump 
instruction manual.

 

Save all instructions. 

Part No. 77X522

Part No. 77X530 or 77X531

Содержание Dyna-Star HF

Страница 1: ...of a low fluid level For professional use only Low Level Indicator Part No 77X522 Includes sight glass electric low level switch and cable Requires follower plate Cannot be used with Auto Fill Shut O...

Страница 2: ...sier if the reservoir has been filled with grease first If a follower plate is not pre installed fill tank at least half full 4 Remove plug a from cover b Discard plug you will not reuse it FIG 2 5 Lo...

Страница 3: ...servoir Short cable is used with 60 reservoirs Long cable is used with 90 reservoirs Remove and discard the cable you are not using and the Notice label attached to the cables 10 For easy wiring make...

Страница 4: ...nst the surface of the follower plate 13 Install follower plate m on top of grease inside res ervoir h with the cone side facing up Press fol lower plate firmly into grease to remove all air pockets 1...

Страница 5: ...llower plate m as shown in FIG 10 NOTE When pump is correctly installed the breather t will be below the control box s as shown in FIG 11 17 Replace screws e and washers f and wrench tighten securely...

Страница 6: ...to PINS 1 and 3 of the DIN Form A Field Wireable Adapter See FIG 14 2 Connect Dyna Star pump to main power source 3 Start system following pump start up procedure included in the Dyna Star HP or HF Pu...

Страница 7: ...red is partially vis ible at the top of the sight glass This appearance indi cates that the lubrication supply container is approaching the low level mark and needs to be refilled Low Level Mark FIG...

Страница 8: ...FIG 19 Wrench tighten it in place 3 To determine the level of the fluid remaining in the reservoir loosen and remove dip stick c from res ervoir cover b 4 Use a clean rag to wipe oil grease from end o...

Страница 9: ...on low level Operating temperature range 50 F to 150 F 45 C 65 C Electrical Ratings Switching Power 10 Watt Max Switching Current 0 4A Max Switching Voltage 5 32 VDC Contact Resistance 0 150 Initial O...

Отзывы: