background image

Installation

308390N

5

Installation 

Grounding

Pump: 

Use ground wire and clamp as shown in F

IG

. 1. 

To order a Grounding Wire and Clamp kit, order Part No. 
222011.

Hydraulic hoses and fluid outlet hoses:

 Use only 

electrically conductive hoses.

Hydraulic power supply:

 Follow manufacturer’s rec-

ommendations.

Any pails used when flushing: 

Use only metal, 

grounded pails when flushing. Make firm metal-to-metal 
contact between the metal part of the dispense valve 
and the pail. Use the lowest possible pressure.

To grounding the pump: 

Remove the ground screw (Z) 

and insert through the ye of the ring terminal at the end 
of ground wire (Y). Fasten the ground screw back onto 
the pump and tighten securely. Connect the other end of 
the ground wire to a true earth ground.

Accessories

Suction Hose Kit, Part No. 236054

A suction tube kit is available for siphoning from 55-gal-
lon containers

Intake Tube

 (not shown)

To install, apply PTFE tape to the female threads at the 
top of the tube. Screw the tube tightly onto the intake 
housing of the stubby pump.

Low-level Cutoff Valve, Part No. 203688

To install, screw the low-level cutoff valve into the bot-
tom of the pump intake tube or the suction tube. This 
valve closes the pump intake when the fluid level is low, 
causing the pump to stall to avoid running dry.

Ground Wire, Part No. 222011

A ground wire is required.

Pump Outlet Drain Valve, Part No. 210658

Install a drain valve (C) close to the pump fluid outlet to 
assist in relieving fluid pressure in he pump when the 
pump is shut off. 

Thermal Relief Kit, Part No. 235998

Install a Thermal Relief Kit (S) at the pump fluid outlet.

The equipment must be grounded to reduce the risk 
of static sparking and electric shock. Electric or static 
sparking can cause fumes to ignite or explode. 
Improper grounding can cause electric shock.  
Grounding provides an escape wire for the electric 
current.

F

IG

. 1

Y

Z

NOTICE

Pump Outlet Drain Valve

A pump outlet drain valve (C) is required in the sys-
tem. This valve helps relieve pressure in the displace-
ment pump and hose when shutting down the system 
and in case of a clogged outlet hose. Install the valve 
close to the pump.

Содержание Dyna-Star 236753

Страница 1: ...bar Maximum Hydraulic Inlet Pressure 375 psi 2 6 MPa 26 bar Maximum Fluid Outlet Pressure Important Safety Instructions Read all warnings and instructions in this manual Save these instructions The pu...

Страница 2: ...the Pump 8 Starting the Pump 8 If the Reciprocator Leaks at the Fluid Fittings 9 Shutdown 9 Troubleshooting 10 Repair 11 Replacing the Throat Seals 11 Disconnecting Reciprocator and Displacement Pump...

Страница 3: ...rags and spilled or open containers of solvent and gasoline Do not plug or unplug power cords or turn lights on or off when flammable fumes are present Ground all equipment in the work area Use only g...

Страница 4: ...ARD Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin inhaled or swallowed Read MSDSs to know the specific hazards of the fluids you are using Store hazardous...

Страница 5: ...Screw the tube tightly onto the intake housing of the stubby pump Low level Cutoff Valve Part No 203688 To install screw the low level cutoff valve into the bot tom of the pump intake tube or the suc...

Страница 6: ...ll mounting bracket P N 236778 see manual 308394 S Thermal Relief Kit required Hydraulic System Keep the hydraulic system clean The hydraulic supply system must be kept clean at all times to reduce th...

Страница 7: ...ne M and mini mum 3 4 in return line D on the reciprocator Contact your Graco representative for details of line sizing A pressure reducing valve K circulates excess hydraulic fluid pressure back to t...

Страница 8: ...pply line shutoff valve H 3 Adjust the flow control valve L to limit the hydraulic flow to no more than 3 gpm 11 lpm which is approximately 60 cycles per minute NOTE If Graco Part No 236864 hydraulic...

Страница 9: ...hten the fittings 16 17 25 which are self sealing and have replaceable o rings If leaking persists change the o rings FIG 3 Shutdown Relieve the pressure whenever shut down See Pres sure Relief Proced...

Страница 10: ...Check and repair See page 17 Empty supply container Refill and reprime Do not allow pump to run dry Monitor closely or use a low level cutoff valve Pump runs but output low on up and or down stroke P...

Страница 11: ...lush the pump if possible and stop it with the piston rod in the lowest position 2 Relieve the pressure See Pressure Relief Proce dure on page Pressure Relief Procedure 8 3 Disconnect the outlet hose...

Страница 12: ...er 118 7 Using a strap wrench on the pump cylinder 118 screw it tightly into the base 115 Reciprocator Repair NOTE Clean and inspect all parts for wear or damage Replace parts as needed For the best r...

Страница 13: ...e piston 35 to screw it off the rod NOTE Be careful not to scratch the outside of the dis placement rod or the inside of the cylinder 8 Visually inspect the spring 36 If there is wear or damage procee...

Страница 14: ...nto the displacement rod 54 Torque to 30 40 ft lb 41 54 N m 12 Install the o ring 18 in the deep lower groove of the piston 35 and install the seal 38 over the o ring Install the piston bearing 37 aro...

Страница 15: ...7 23 17 If the tie rods 49 were removed reinstall them with the short threaded end up The other end should be screwed about 9 16 into the bottom cylinder cap 47 NOTE When reinstalling the cylinder 39...

Страница 16: ...116 Place assembly in a vise and torque to 155 175 ft lb 210 237 N m Make sure the o ring 112 in the outside groove of the pump cylinder 9118 is in good condition Push the cylinder up into the adapte...

Страница 17: ...ngs and packings when you disassemble the pump The parts list on page 19 gives the recommended parts to keep on hand 1 If possible flush the pump 2 Relieve pressure See Pressure Relief Procedure on pa...

Страница 18: ...Parts 18 308390N Parts 7 6 8 22 52 31a 49 37 36 20 9 32 25 27 43 57 14 33 31 17 26 16 44 13 13 39 40 35 18 38 11 54 19 11 55 55 45 47 34 56 12 24 5...

Страница 19: ...KING o ring buna N 1 19 114231 NUT lock hex 1 20 108437 SPRING compression 1 22 108952 PACKING block v 1 24 112566 SCREW cap socket hd 4 25 112568 ADAPTER pipe female 1 26 112569 UNION swivel 1 27 155...

Страница 20: ...r See Parts on page X 1 103 100133 WASHER lock 3 8 4 104 101178 BALL metallic 1 105 102637 SCREW cap hex hd 3 8 16 x 1 1 2 4 106 108001 BALL metallic sst 1 107 110064 PLUG pipe vented 1 8 27 npt f 1 1...

Страница 21: ...placement Pump Wetted Parts Aluminum Steel Nitrile Polyurethane Sound Pressure 77 dB A Sound pressure reading taken with pump operating at 66 cycles per minute Sound pressure measured per CAGI PNEUROP...

Страница 22: ...f the equipment does not disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY...

Отзывы: