background image

Performance Charts 

22

308360D

Performance Charts

To find Fluid Outlet Pressure (psi/bar) at a specific 
fluid flow (gpm/lpm):

1. Locate desired flow along bottom of chart.

2. Follow vertical line up to intersection with selected 

fluid outlet pressure curve (black). Follow left to 
scale to read fluid outlet pressure.

To find Pump Air Consumption (m

3

/scfm) at a 

specific fluid flow (gpm/lpm) and air pressure 
(psi/bar):

1. Locate desired flow along bottom of chart.

2. Read vertical line up to intersection with selected air 

consumption curve (gray). Follow right to scale to 
read air consumption.

NOTE:

 Recommended pump speed for continuous 

operation (to shaded area) is 60 cpm.

Model 237516 Bulldog Pump

Model 237517 Senator Pump

Key

Black Curve Fluid Outlet Pressure
Gray Curve

Air Consumption

A

7 bar (100 psi) Air Pressure

B

4.9 bar (70 psi) Air Pressure

C

2.8 bar (40 psi) Air Pressure

100

7.6

2.80

12.5

50

75

15.2

35

62.5

A

B

C

A

B

C

140

175

200

5.60

22.8

11.4

3.8

50

1.40

150

4.20

250

7.00

37.5

60

19.0

105

70

25

cycles/min

psi 

bar

scfm

m

3

/min

FLUID FLOW (NUMBER 10 WEIGHT OIL)

gpm

lpm

FLUID PRESSURE

100

7.6

2.80

12.5

50

75

15.2

35

62.5

A

B

C

A

B

C

22.8

11.4

3.8

50

1.40

150

4.20

37.5

60

19.0

105

70

25

FLUID FLOW (NUMBER 10 WEIGHT OIL)

gpm

lpm

cycles/min

scfm

m

3

/min

psi 

bar

FLUID PRESSURE

Содержание Dura-Flo 1200

Страница 1: ...i 0 7 MPa 7 bar Maximum Air Input Working Pressure 237517 Pump Series A 13 1 Ratio with Senator Air Motor 1300 psi 9 MPa 90 bar Maximum Fluid Working Pressure 100 psi 0 7 MPa 7 bar Maximum Air Inlet W...

Страница 2: ...ired Tools 12 Disconnect the Displacement Pump 12 Connect the Displacement Pump 12 Disassemble the Displacement Pump 14 Assemble the Displacement Pump 16 Parts 19 Packing Kits 21 Performance Charts 22...

Страница 3: ...when equipment is not in use Check equipment daily Repair or replace worn or damaged parts immediately with genuine manufacturer s replacement parts only Do not alter or modify equipment Alterations...

Страница 4: ...ug power cords or turn power or light switches on or off when flammable fumes are present Use only grounded hoses Hold gun firmly to side of grounded pail when triggering into pail Do not use pail lin...

Страница 5: ...hen flushing or relieving pressure hold metal part of the spray gun dispense valve firmly to the side of a grounded metal pail then trigger the gun valve Accessories Install the following accessories...

Страница 6: ...r line drop to drain off moisture Second bleed type air valve K isolates the air line accessories for servicing NOTE Locate upstream from all other air line accessories Fluid Line Fluid filter L with...

Страница 7: ...equired for pump F Pump air regulator G Air manifold H Electrically conductive air supply hose J Air line filter K Bleed type master air valve for accessories L Fluid filter M Fluid drain valve requir...

Страница 8: ...e Equipment Flush before fluid can dry in the equipment at the end of the day before storing and before repairing equipment Flush at the lowest pressure possible Check connectors for leaks and tighten...

Страница 9: ...as a priming valve until the fluid flows from the valve Close the valve NOTE When changing fluid containers with the hose and gun already primed open the drain valve M to help prime the pump and vent...

Страница 10: ...f Procedure page 8 2 Follow Flush the Equipment page 8 NOTICE Always use the lowest air pressure necessary to get the desired results Higher pressures cause premature tip and pump wear NOTICE Always f...

Страница 11: ...he displacement rod Clean the rod always stop the pump at the bottom of its stroke keep the wet cup 1 3 filled with a compatible solvent Motor parts are dirty worn or damaged Clean or repair see the s...

Страница 12: ...reconnects it to the motor 3 Screw the nuts 108 onto the tie rods 105 Torque the nuts to 81 89 N m 60 66 ft lb 4 Screw the coupling nut onto the motor shaft MS loosely Hold the motor shaft flats with...

Страница 13: ...intenance 308360D 13 FIG 2 Model 237516 Shown Torque to 136 149 N m 100 110 ft lb 1 2 Torque to 196 210 N m 145 155 ft lb Torque to 81 89 N m 60 66 ft lb 3 V 108 U 109 2 1 106 107 MS 110 105 101 1 2 3...

Страница 14: ...ing 18 from the outlet housing 7 b Gently pull the cylinder and valve housing straight out of the outlet housing the displacement rod 1 and piston assembly will come out with these parts c Place the v...

Страница 15: ...IG 3 FIG 4 03794A BS 19 17 8 Joint A 2 1 7 9 18 Joint B Torque to 325 353 N m 240 260 ft lb 1 2 Lubricate Torque to 190 217 N m 140 160 ft lb 3 1 1 2 2 3 03793A 1 10 16 1 10 11 16 Torque to 386 407 N...

Страница 16: ...erial see Packing Kits page 21 6 Apply anti seize 20 and install the packing nut 2 loosely into the outlet housing 7 7 Lubricate the piston packings Slide the displacement rod 1 and piston assembly do...

Страница 17: ...N m 240 260 ft lb This will torque both cylinder joints A and B See FIG 3 page 15 17 Using a pipe wrench torque the intake valve 19 to 190 217 N m 140 150 ft lb See FIG 3 page 15 18 Torque the packin...

Страница 18: ...Packing Detail at left Torque to 190 217 N m 140 160 ft lb 1 2 7 OV 10 9 18 16 SS 17 BS 8 11 PG PS PV 8 14 5 2 Ref 4 3 6 7 Ref 10 Ref 9 Ref 16 Ref 13 12 15 18 Ref 8 Ref 6 4 6 4 5 4 5 4 4 4 3 2 3 9 7 1...

Страница 19: ...1 Replacement safety labels tags and cards are available at no cost These parts are included in Connection Kit 235417 For applications requiring stainless steel tie rods order Connection Kit 235418 1...

Страница 20: ...ball piston stainless steel 1 11 102972 BALL piston stainless steel 0 875 in 22 2 mm diameter 1 16 222951 HOUSING seat piston valve stainless steel with tungsten carbide seat 1 17 108001 BALL intake...

Страница 21: ...t male stainless steel 1 13 184230 GLAND piston male stainless steel 1 14 109310 V PACKING piston PTFE 5 15 184180 GLAND piston female stainless steel 1 20 123174 ANTI SEIZE not shown 1 0805 0806 14 1...

Страница 22: ...ow right to scale to read air consumption NOTE Recommended pump speed for continuous operation to shaded area is 60 cpm Model 237516 Bulldog Pump Model 237517 Senator Pump Key Black Curve Fluid Outlet...

Страница 23: ...64 in 94 28 mm 3 712 in 11 1 mm 0 437 in DIA 4 94 28 mm 3 712 in 0653 Three M16 x 2 0 Holes Pump Model A B C D E F G 237516 1134 mm 44 65 in 590 mm 23 23 in 544 mm 21 42 in 257 mm 10 12 in 2 in np f 1...

Страница 24: ...0 mm Displacement pump effective area 1 86 in 2 12 cm2 Maximum pump operating temperature 180 F 82 C Air inlet size 3 4 npsm f Fluid inlet size 2 in npt f Fluid outlet size 1 in npt f Weight 240 lb 10...

Страница 25: ...in 2 12 cm2 Maximum pump operating temperature 180 F 82 C Air inlet size 3 4 npsm f Fluid inlet size 2 in npt f Fluid outlet size 1 in npt f Weight 240 lb 109 kg Wetted parts 316 440 and 17 4 PH Grad...

Страница 26: ...material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRAN...