Attach the Power Valve
1. Remove the air line from the air motor.
2. Apply thread sealant to all male fittings and install
the power valve as shown.
NOTE:
Verify that port “1” of the power valve will receive
the incoming air supply once installed.
3. Connect the air supply line.
4.
DataTrak:
Connect the power valve to the DIN con-
nector on the D-Sub harness of the remote Data-
Trak.
Customer Provided PLC Machine Monitoring
Kit:
Connect the power valve to the DIN connector
of the control box.
Attach the Cycle Counter
1. Attach the cycle counter to the air motor with the
screw provided on the cycle counter.
2.
DataTrak:
Connect the cycle counter to the blue
labeled connector on the D-Sub harness.
Customer Provided PLC Machine Monitoring
Kit:
Connect the sensor to the 4 meter (13 feet)
M12 gray connector of the control box.
Attach and Adjust Drum
Low/Empty Sensor
1. Position ram at desired level (low or empty).
2. Attach the sensor bracket to the mounting bracket
or ram cylinder.
3. To measure either drum low or drum empty, attach
the sensor to the sensor bracket.
4. Attach the piston collar to the ram piston rod, near
the top, so it passes in front of the sensor at the cor-
rect level for drum low or drum empty.
5. Make precise adjustments by moving the sensor
within the slot on the sensor bracket.
6.
DataTrak:
Connect the sensor to the yellow labeled
connector on the D-Sub harness.
Customer Provided PLC Machine Monitoring
Kit:
Connect the sensor to the 1 meter (3 feet) M12
gray connector of the control box.
DataTrak
Customer Provided
PLC Machine Monitor-
ing Kit