Installation
311103C
5
Installation
Installing the Tip and Guard
(Fig. 1 and Fig. 2)
1
Without the spray tip installed, start sprayer, turn the knob
on the Low Overspray CleanShot Valve counter-clockwise
to the FLUSH position (Fig. 2).
2
Flush and prime the spray system.
3
Follow the
Pressure Relief Procedure
described in the
warning pages of this manual.
4
Install the spray tip.
5
Turn the knob of the Low Overspray CleanShot Valve to
SPRAY (Fig. 2).
6
Rotate the Low Overspray CleanShot Valve to any desired
position within 180°. Do not use any tools.
7
Refer to your separate gun instruction manual for
operating and tip cleaning instructions.
8
This adapter is repairable.
Flush and Spray
The Low Overspray CleanShot Valve provides two set-
tings: SPRAY and FLUSH. The valve is factory set to the
SPRAY position for spraying at pressures above 700 psi
(4.8 MPa, 48 bar). Turn the valve (override) to the
FLUSH position for flushing, cleaning, priming and
relieving pressure. FLUSH is also used for low pressure
spraying applications below 1000 psi (6.9 MPa, 69 bar).
WARNING
To reduce the risk of serious bodily injury from fluid
injection or splashing in the eyes or on the skin, stop
using the nozzle immediately if it starts to leak or can-
not be turned easily.
WLD
Fig.1
CAUTION
To avoid damage to the o-ring in the swivel:
•
Relieve fluid pressure before rotating the swivel.
•
Do not soak the entire swivel in solvent.
Fig. 2
WLD