background image

Maintenance

Maintenance

Maintenance

Maintenance

Maintenance

Maintenance

Maintenance Schedule

Schedule

Schedule

Establish a preventive maintenance schedule
based on the pump’s service history. Scheduled
maintenance is especially important to prevent spills
or leakage due to diaphragm failure. A clogged
muffler may restrict pump performance. Inspect
air lines and muffler media regularly to maintain
performance.

Lubrication

Lubrication

Lubrication

The pump is lubricated at the factory. It is designed
to require no further lubrication for the life of the
packings. There is no need to add an inline lubricator
under normal operating conditions.

Tighten

Tighten

Tighten Threaded

Threaded

Threaded Connections

Connections

Connections

Before each use, check all hoses for wear or damage
and replace as necessary. Check to be sure all
threaded connections are tight and leak-free. Check
mounting bolts. Check bolts. Tighten or retorque as
necessary. Although pump use varies, a general
guideline is to retorque bolts every two months. See

Torque Instructions, page 22

.

Flushing

Flushing

Flushing and

and

and Storage

Storage

Storage

• Flush before fluid can dry in the equipment, at the

end of the day, before storing, and before repairing
equipment.

• Flush at the lowest pressure possible. Check

connectors for leaks and tighten as necessary.

• Use solvent that is compatible with the equipment

wetted parts and the material being dispensed.

• Always flush the pump and relieve the pressure

before storing it for any length of time.

NOTICE

NOTICE

NOTICE

Flush the pump often enough to prevent the fluid
you are pumping from drying or freezing in the
pump and damaging it.

Storage:

Storage:

Storage: Pumps must be stored in an environment
where they are clean, dry, and protected from
extreme temperatures, UV radiation, and vibration.
Graco recommends an ambient temperature range of
60°F-80°F (15°C-25°C), with a humidity level below
65%.

334793E

15

Tel:  866-777-6060 
Fax: 866-777-6383

Springer Pumps, LLC

Website: www.springerpumps.com 

Int'l: +001 267 404 2910

Содержание ChemSafe 307

Страница 1: ...d approved for for for use use use in in in European European European explosive explosive explosive atmosphere atmosphere atmosphere locations locations locations Important Important Important Safety Safety Safety Instructions Instructions Instructions Read all warnings and instructions in this manual Save Save Save these these these instructions instructions instructions 100 psi 0 7 MPa 7 0 bar ...

Страница 2: ...Adjust the Pump 13 Pressure Relief Procedure 14 Pump Shutdown 14 Maintenance 15 Maintenance Schedule 15 Lubrication 15 Tighten Threaded Connections 15 Flushing and Storage 15 Troubleshooting 16 Repair 18 Disassemble the Fluid Section 18 Disassemble the Center Section 19 Reassemble the Center Section 19 Reassemble the Fluid Section 20 Torque Instructions 22 Parts 24 Kits 26 Dimensions 27 Performanc...

Страница 3: ...ses Hold gun firmly to side of grounded pail when triggering into pail Do not use pail liners unless they are antistatic or conductive Stop Stop Stop operation operation operation immediately immediately immediately if static sparking occurs or you feel a shock Do not use equipment until you identify and correct the problem Keep a working fire extinguisher in the work area Route exhaust away from ...

Страница 4: ...or the environment in which you are using it Use equipment only for its intended purpose Call your distributor for information Route hoses and cables away from traffic areas sharp edges moving parts and hot surfaces Do not kink or over bend hoses or use hoses to pull equipment Keep children and animals away from work area Comply with all applicable safety regulations THERMAL THERMAL THERMAL EXPANS...

Страница 5: ...AZARD HAZARD Equipment surfaces and fluid that s heated can become very hot during operation To avoid severe burns Do not touch hot fluid or equipment PERSONAL PERSONAL PERSONAL PROTECTIVE PROTECTIVE PROTECTIVE EQUIPMENT EQUIPMENT EQUIPMENT Wear appropriate protective equipment when in the work area to help prevent serious injury including eye injury hearing loss inhalation of toxic fumes and burn...

Страница 6: ...d and and Air Air Air Valve Valve Valve Material Material Material Fluid Fluid Fluid Covers Covers Covers and and and Manifolds Manifolds Manifolds 307PT 307PT 307PT 3 8 in PTFE P01A P01A P01A Polypropylene center with npt air inlet PT3 PT3 PT3 PTFE npt 307UH 307UH 307UH 3 8 in UHMWPE P03A P03A P03A Polypropylene center with bspt air inlet PT4 PT4 PT4 PTFE bspt UH3 UH3 UH3 UHMWPE npt UH4 UH4 UH4 U...

Страница 7: ...27 24X427 24X427 3 8 3 8 3 8 in in in PTFE PTFE PTFE npt npt npt PTFE PTFE PTFE 24X504 24X504 24X504 bspt bspt bspt 24X503 24X503 24X503 npt npt npt PTFE EPDM PTFE EPDM PTFE EPDM Overmolded Overmolded Overmolded 24X536 24X536 24X536 bspt bspt bspt 24X537 24X537 24X537 npt npt npt EPDM EPDM EPDM 24X502 24X502 24X502 bspt bspt bspt 24X501 24X501 24X501 3 8 3 8 3 8 in in in UHMWPE UHMWPE UHMWPE npt n...

Страница 8: ... Cavitation in an AODD pump is the formation and collapse of bubbles in the pumped liquid Frequent or excessive cavitation can cause serious damage including pitting and early wear of fluid chambers balls and seats It may result in reduced efficiency of the pump Cavitation damage and reduced efficiency both result in increased operating costs Cavitation depends on the vapor pressure of the pumped ...

Страница 9: ...nd accessories as well as the stress caused during operation 3 For all mountings be sure the pump is secured with screws through the mounting feet Always mount the pump upright 4 Make sure the surface is flat and that the pump doesn t wobble 5 For ease of operation and service mount the pump so air inlet fluid inlet and fluid outlet ports are easily accessible Accessories Components Accessories Co...

Страница 10: ...l pails placed on a grounded surface Do not place the pail on a nonconductive surface such as paper or cardboard which interrupts grounding continuity Check your system electrical continuity after the initial installation and then set up a regular schedule for checking continuity to be sure proper grounding is maintained Air Air Air Lines Lines Lines 1 Install an air regulator and gauge C to contr...

Страница 11: ...eparately 2 Remove the muffler U from the pump air exhaust port K 3 Install the adaptor from the kit 4 Install a grounded air exhaust hose S If a hose longer than 10 ft 3 m is required use a larger diameter hose Avoid sharp bends or kinks in the hose 5 Place a container T at the end of the air exhaust line to catch fluid in case a diaphragm ruptures If the diaphragm ruptures the fluid being pumped...

Страница 12: ... MPa 0 21 0 34 bar should be adequate for most materials 3 For maximum suction lift wet and dry see Technical Data page 29 For best results always install the pump as close as possible to the material source Minimize suction requirements to maximize pump performance Fluid Fluid Fluid Outlet Outlet Outlet Line Line Line 1 Use grounded flexible fluid hoses See Ground The System page 10 2 Install a f...

Страница 13: ...s to be sure they are tight Use a compatible liquid thread sealant on male threads NOTICE NOTICE NOTICE Do not overtighten fluid inlet and outlet fittings The soft plastic threads can be stripped easily 3 Place the suction tube if used in fluid to be pumped NOTE NOTE NOTE If fluid inlet pressure to the pump is more than 25 of outlet working pressure the ball check valves will not close fast enough...

Страница 14: ... Procedure when you stop pumping and before you clean check or service the equipment 1 Shut off the air supply to the pump 2 Open the dispensing valve if used 3 Open the fluid drain valve to relieve fluid pressure Have a container ready to catch the drainage Pump Pump Pump Shutdown Shutdown Shutdown At the end of the work shift and before you check adjust clean or repair the system follow the Pres...

Страница 15: ...ighten or retorque as necessary Although pump use varies a general guideline is to retorque bolts every two months See Torque Instructions page 22 Flushing Flushing Flushing and and and Storage Storage Storage Flush before fluid can dry in the equipment at the end of the day before storing and before repairing equipment Flush at the lowest pressure possible Check connectors for leaks and tighten a...

Страница 16: ...old Replace ball and seat Dispensing valve is clogged Relieve pressure and clear valve Pump will not cycle or cycles once and stops Diaphragm is ruptured Replace Suction line is clogged Inspect clear Check valve balls are sticky or leaking Clean or replace Diaphragm is ruptured Replace Exhaust is restricted Remove restriction Spool valve is damaged or worn Replace spool valve Air supply is erratic...

Страница 17: ...or damaged Replace Fluid covers are loose Retorque Diaphragm is damaged Replace Pump leaks air externally Manifold fittings are loose Retorque Fluid covers are loose Retorque Pump leaks fluid externally Diaphragms are damaged Replace 334793E 17 Tel 866 777 6060 Fax 866 777 6383 Springer Pumps LLC Website www springerpumps com Int l 001 267 404 2910 ...

Страница 18: ...n wrench to remove the outlet manifold 8 and retainer 11 6 Without scratching the inner bore use a hook to remove the outlet ball retainer 19 Remove the ball 22 and check seat 21 7 Reattach the manifold bolts 29 to keep the fluid cover nuts 18 aligned 8 Remove the nuts 28 and bolts 24 using two 7 mm sockets to hold on one side and to turn the other The nuts 28 will come off of one side Remove the ...

Страница 19: ...e the the the Center Center Center Section Section Section 1 Install the muffler media 15 38 into the muffler Use the new felt mufflers 15 supplied in the rebuild kit Muffler parts must be placed in the exact order shown in the illustration Use the supplied tool 46 to screw the muffler 14 into the exhaust port the port with 2 holes on the bottom 2 Lubricate and install an o ring 35 and then the sh...

Страница 20: ... 18 just to keep the nuts from rotating 3 Repeat steps 1 and 2 for the other fluid cover 4 Install the fluid covers with the top checks toward the air inlet 5 Place two belleville washers 27 with the washer closest to the nut having the rounded side toward the nut and the other washer with the rounded side away from the nut then a flat washer 26 on each tie bolt 24 Thread the first tie bolt 24 thr...

Страница 21: ...then a washer 26 on each bolt Install the bolts 29 just hand tight for now then flip the pump over 13 Assemble the top checks Insert the seat 21 with the chamfered side up the ball 22 and the outlet ball retainer 19 14 Carefully remove the manifold bolts 29 from the top of the fluid covers 6 keeping nuts 18 aligned 15 Align the outlet manifold 8 with the dowels on the top of the body 16 Align the ...

Страница 22: ... screwdriver Carefully work the screwdriver under the lip of each cap and gently pry it off 2 Start all fluid cover screws a few turns Then turn down each screw just until head contacts cover 3 Turn each screw by 1 2 turn or less working in a crisscross pattern to specified torque 4 Repeat for fluid manifolds Assembly Torque Re Torque Fluid Covers 20 in lb 2 3 N m 15 in lb 1 7 N m Fluid Manifolds ...

Страница 23: ...Notes Notes Notes Notes 334793E 23 Tel 866 777 6060 Fax 866 777 6383 Springer Pumps LLC Website www springerpumps com Int l 001 267 404 2910 ...

Страница 24: ...te using PFPE grease 17G558 included in all Center and Fluid Section Rebuild kits 2 Follow Torque Instructions page 22 24 334793E Tel 866 777 6060 Fax 866 777 6383 Springer Pumps LLC Website www springerpumps com Int l 001 267 404 2910 ...

Страница 25: ...1 2 in outlet top PTFE 2 20 17F104 RETAINER ball 1 2 in inlet bottom PTFE 2 21 SEAT 4 Ref Ref Ref Part Part Part Description Description Description Qty Qty Qty 22 17F252 BALL 1 2 in PTFE 4 pack 1 24 17F181 BOLT tie stainless steel 6 DIAPHRAGM 2 pack 17F245 Buna n 17F246 EPDM 25 17F247 PTFE 1 26 17F193 WASHER 4 mm 20 pack 1 27 17F194 WASHER belleville 0 375 in diameter 50 pack 1 28 17F179 NUT hex ...

Страница 26: ...let Ball Retainer 2 21 Seat 4 22 Check Ball 4 Diaphragm PTFE Overmolded Kit 17F120 EPDM Kit 17F121 25 Buna N Kit 17F122 2 37 Plug 20 48 PFPE Lubricant 1 Air Air Air Motor Motor Motor Assembly Assembly Assembly Kit Kit Kit 17F596 17F596 17F596 Kit Includes Ref Ref Ref Description Description Description Qty Qty Qty 2 Main Sleeve Assembly 1 3 Sleeve Cap 2 4 Center Sleeve Assembly 1 17 Glide Shaft Se...

Страница 27: ...135 mm C C C 3 0 in 76 mm D D D 5 9 in 150 mm E E E 4 9 in 124 mm F F F 7 6 in 193 mm G G G 3 5 in 89 mm H H H 3 0 in 76 mm J J J 3 0 in 76 mm K K K hole hole hole diameter diameter diameter 0 3 in 7 mm 334793E 27 Tel 866 777 6060 Fax 866 777 6383 Springer Pumps LLC Website www springerpumps com Int l 001 267 404 2910 ...

Страница 28: ...4 8 bar C C C 40 psi 0 28 MPa 2 8 bar Air Air Air Consumption Consumption Consumption Approximate Approximate Approximate Cycles Cycles Cycles per per per Minute Minute Minute How How How to to to Read Read Read the the the Charts Charts Charts 1 Locate fluid flow rate along bottom of chart 2 Follow vertical line up to intersection with selected operating air pressure curve 3 Follow left to scale ...

Страница 29: ...ezing or crystallization of the fluid inside or outside of the pump Running the pump at temperatures below freezing may accelerate the wear of the elastomer components in the pump 32 F 0 C Air consumption at maximum flow 9 3 scfm 0 26 scmm Fluid flow per cycle 0 011 gallons 0 04 liters Maximum free flow delivery 6 7 gpm 25 4 lpm Maximum pump speed 610 cycles per minute Weight PTPE UHMW 6 lb 4 lb 2...

Страница 30: ...D AND DISCLAIMS DISCLAIMS DISCLAIMS ALL ALL ALL IMPLIED IMPLIED IMPLIED WARRANTIES WARRANTIES WARRANTIES OF OF OF MERCHANTABILITY MERCHANTABILITY MERCHANTABILITY AND AND AND FITNESS FITNESS FITNESS FOR FOR FOR A A A PARTICULAR PARTICULAR PARTICULAR PURPOSE PURPOSE PURPOSE IN IN IN CONNECTION CONNECTION CONNECTION WITH WITH WITH ACCESSORIES ACCESSORIES ACCESSORIES EQUIPMENT EQUIPMENT EQUIPMENT MATE...

Отзывы: