Installation

Electric Crossover Setup

NOTE: During system operation, as the ram ap-
proaches the drum bottom, the top of the ram contacts
the empty level indicator kit’s limit valve switch. The
switch shuts off air to the ram air motor via a solenoid
valve. As the valve stops air to one air motor, it starts
air to the other air motor. This allows constant material
flow and changing out of material drums.

The position of the empty level indicator kit (B) on the
ram determines when the ram air motor is turned on
and off. During operation, this position can be adjusted
as desired.

1.

Install crossover unloader (1) on ram assembly,
using U-bolt (3), washer (4) and nut (5) as shown
in Parts. Connect air supply.

WARNING

ELECTRIC SHOCK HAZARD
Do not open the electrical control panel,
unless you are a trained professional.

Before opening the control panel, make sure that
all power has been removed from the control panel.

2.

Connect electrical connectors to cross-over 
unloader (see Fig. 2). Refer to Schematic, 
Fig. 3.

Fig. 2

3.

Install solenoid valve (7) and connect electrical
connector as shown in Parts.

4.

Install 2 empty level kit assemblies (9) on each
ram assembly, using attaching parts, as shown in
Parts drawing.

5.

Connect electrical connector to each empty level
kit assembly (9). Refer to Schematic, Fig. 3.

Fig. 3

6.

Adjust limit switch (9c) to trip with the ram plate 1”
from base plate (see Parts).

Содержание C59519

Страница 1: ...Crossover Kit 250 psi 1 7 MPa 17 2 bar Maximum Air Inlet Pressure Part No C59519 Series A Electric Crossover Kit Part No C59520 Series A Electric Crossover Kit Table of Contents Warnings 2 Component I...

Страница 2: ...ent only for its intended purpose If you are not sure call your Graco distributor Do not alter or modify this equipment Use only genuine Graco parts and accessories Check equipment daily Repair or rep...

Страница 3: ...ommended by the fluid and solvent manufacturer Avoid exposure to heated material fumes Provide adequate ventilation FIRE EXPLOSION AND ELECTRIC SHOCK HAZARD Improper grounding poor air ventilation ope...

Страница 4: ...ve 2 B Empty Level Kit 2 C Limit Switch 2 D Unloader Cross over Panel 8584A A C B A B Supply Unit A Supply Unit B NOTE Viewed from the loading direction C D CL3 CL1 CL4 CL2 8891A A C hidden B A D CL3...

Страница 5: ...and qualified personnel to reduce the risk of serious injury and electric shock Observe all local codes and regulations regarding electrical wiring When installing in a flammable atmosphere hazardous...

Страница 6: ...nstall crossover unloader 1 on ram assembly using U bolt 3 washer 4 and nut 5 as shown in Parts Connect air supply WARNING ELECTRIC SHOCK HAZARD Do not open the electrical control panel unless you are...

Страница 7: ...55333 KIT ASSEMBLY empty level includes items 9a through 9g 2 9a C32111 S LIGHT FIXTURE 1 9b C07451 S CONNECTOR receptacle 1 9c C07368 S LIMIT SWITCH w lever 1 9d C55409 S BRACKET limit switch 1 9e C1...

Страница 8: ...h 9n 2 9a C32111 S LIGHT FIXTURE 1 9b C07451 S CONNECTOR receptacle 1 9c C07368 S LIMIT SWITCH w lever 2 9d 617352 S BRACKET limit switch 1 9e 110344 S SCREW cap 2 9f 100016 S WASHER lock 2 9g 100643...

Страница 9: ...310295 9 Notes...

Страница 10: ...anty shall be as set forth above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or property or any...

Отзывы:

Похожие инструкции для C59519