18 307932

Parts

Model 245185, Series A (240 Volt Heater)
Model 245186, Series A (480 Volt Heater)

Ref
No.

Part No.

 Description

Qty

Ref
No.

Part No.

 Description

Qty

1

245117

33:1 BULLDOG PUMP
See 309340 for parts

1

2

206294

BRACKET, wall, pump

1

4

218029

FLUID FILTER
See 307273 for parts

1

5

100509

PLUG, pipe, sq hd; 1/4 npt

4

6

150286

ADAPTER; 3/8 npt (m x f)

1

7

210658

DRAIN VALVE; 3/8 npt(mbe)
See 306861 for parts

1

8

206197

AIR REGULATOR
See 308168 for parts

1

11

116401

ELBOW, street, 90

; (f) 1 11–1/2 x 1–1/4

11–1/2(f); zinc-plated malleable iron

1

12

116402

ADAPTER; (f) 1 11–1/2 x 1–1/4
11–1/2(f); zinc–plated malleable iron

1

14

113269

BLEED VALVE, red-handled;
1/2 npt (m x f)

1

15

206205

MANIFOLD, air; 3/4 npsm(f)

1

16

100960

GAUGE, air

1

17

100840

ELBOW, street; 90

; 1/4 npt (m x f)

1

18

100403

PLUG, pipe; 1/8 npt

1

19

214952

HOSE, air; 3/4 in. (19 mm) ID; 
3/4 npt(m) x 1/2 npt(m); 
16 in. (406 mm) long

1

20

100101

SCREW, cap, hex hd; 
3/8–16 x 1 in. (25 mm) long

4

21

100133

WASHER, spring lock; 3/8 in.

4

22

100131

NUT, hex; 3/8–16

5

24

244516

HOSE, siphon; nylon; 1 in. npt;
6 ft (1.8 m) long

1

25

206266

SUCTION TUBE; 3/4 npt(f)

1

26*

183982

BRACKET, wall, heater

2

27*

175013

NIPPLE; 3/4 npt

1

28*

166590

ELBOW, street, 3/4 npt(m x f)

1

29*

235132

CHECK VALVE; 3/4 npt(m) x 3/4 npt(f); 
includes items 29a–29e

1

29a

235133

. SEAT, valve

1

29b

111691

. O-RING; fluoroelastomer

1

29c

101190

. BALL

1

29d

181492

. GUIDE, ball

3

29e

187861

. HOUSING, valve

1

30*

158556

COUPLING, hex pipe; 
1/2 npt(f) x 3/4 npt(f)

1

31*

H55003

HOSE, fluid; nylon; 1/2 in. (12.7 mm) ID;
1/2 npt (fbe); 3 ft (0.9 m) long

3

32*

158683

ELBOW, 90

; 1/2 npt (m x f)

2

33*

156849

NIPPLE; 3/8 npt

2

34*

159801

UNION, adapter, 90

;

3/8 npt(f) x 1/2 npsm(f) swivel

2

35*

165198

NIPPLE, reducing; 1/4 npt(m) x
3/8 npt(m)

1

36*

110110

SEALANT, pipe; sst; 6 ml (not shown) 1

37

207296

HOSE, fluid; PTFE

 

tube 

w/braid cover; 13/32 in. ID;

 

cpld 3/8 npt (mbe); 31 in. (0.8 m) long 1

38

207411

UNION, adapter, 45

;

3/8 npt(f) x 3/8 npsm(f) swivel

1

39

100176

BUSHING, hex; 1/4 npt(f) x 3/8 npt(m) 2

40

214711

BALL VALVE, three-way; 1/4 npt(m);
See 306861 for parts

1

41

205169

HOSE, fluid; nylon; 3/8 in. ID;
3/8 npsm (fbe); 3 ft (0.9 m) long

1

42

167905

TUBE, return; 3/8 npt(m)

1

43

206994

THROAT SEAL LIQUID
8 oz (0.5 liters); not shown

1

44

245863 VISCON

 

HP HEATER, 240 Volt;

used on Model 245185
see manual 309524

2

245864 VISCON

 

HP HEATER, 480 Volt;

used on Model 245186
see manual 309524

2

45

237569

GROUNDING WIRE AND CLAMP

1

47

100322

WASHER, lock; 3/8 in.

2

48

500566

TEE; 1 in. female

1

49

100615

BUSHING; 3/4 npt(m) x 1/4 npt(f)

1

51

290074

LABEL, warning

1

52

100474

COUPLING, pipe

1

53

158555

NIPPLE, reducing; 1 npt x 3/4 npt

1

54

158585

FITTING, nipple

1

55

158586

BUSHING; 1 npt(m) x 3/4 npt(f)

1

62

502265

BUSHING, reducer, pipe

2

64*

158491

NIPPLE, 1/2 npt

3

*

Included in Dual Heater Mounting Kit 222311. Required to
convert Model 245187 or 253697 Sprayers to a heated
unit. The heaters are not included in this kit and must be
ordered separately, by desired voltage (see page 10).

Included in Circulating Kit 222312. Required to convert
Model 245187 or 253697 Sprayers to a circulating unit.

Replacement Danger and Warning labels, tags and cards
are available at no cost.

Содержание Bulldog 245185

Страница 1: ...ximum Air Input Pressure Part No 245185 Series B 240 Volt Heater Part No 245186 Series B 480 Volt Heater For heated spray applications 3000 psi 20 7 MPa 207 bar Maximum Fluid Working Pressure 90 psi 6...

Страница 2: ...quipment only for its intended purpose If you are not sure call your Graco distributor Do not alter or modify this equipment Check equipment daily Repair or replace worn or damaged parts immediately D...

Страница 3: ...r to the gun manual Be sure the gun trigger safety operates before spraying Lock the gun trigger safety when you stop spraying Follow the Pressure Relief Procedure on page 14 if the spray tip clogs an...

Страница 4: ...e of debris including solvent rags and gasoline Electrically disconnect all equipment in the spray area Extinguish all open flames or pilot lights in the spray area Do not smoke in the spray area Do n...

Страница 5: ...ee Fig 1 Loosen the grounding lug locknut W and washer X Insert one end of a 1 5 mm 12 ga minimum ground wire 45 into the slot in lug Z and tighten the locknut securely Connect the other end of the wi...

Страница 6: ...es ports for connect ing lines to air powered accessories The fluid filter 4 includes a 60 mesh 250 mi cron stainless steel element to filter particles from the fluid as it leaves the pump The fluid d...

Страница 7: ...required for pump 15 Air Manifold 24 Suction Hose 25 Suction Tube 45 Ground Wire required see page 5 for installation instructions ACCESSORIES YOU MUST SUPPLY A Electrically Conductive Air Hose B Air...

Страница 8: ...eated system 1 Mount the pump wall bracket 2 5 ft 1 5 m above the floor Be sure the wall is strong enough to support the weight of the pump and accessories fluid hoses and stress caused during pump op...

Страница 9: ...4 Use M8 or 5 16 in bolts of the appropriate length and lockwashers not supplied to fasten the heater brackets to the wall 5 Bring the hose 31a from the inlet elbow 32a of the lower heater 44a and co...

Страница 10: ...d hose for use with airless heated systems Includes an in line fluid filter circulat ing manifold and 3 ft 0 9 m whip hose Installing Dual Heater Mounting Kit 222311 WARNING Before installing the heat...

Страница 11: ...he lower heater See Fig 4 8 Install the bushing 62 and a 3 8 npt nipple 33 in the lower heater s outlet Screw the rigid end of the union 34 onto this nipple and screw the swivel end of the union onto...

Страница 12: ...4 fittings 52 and 53 and suction tube 25 4 Install the CIRC end of the three way ball valve 40 in the bushing 49 Screw a bushing 39 onto the IN branch of the three way valve Con nect the rigid end of...

Страница 13: ...red heater voltage see page 10 Part of the heater 44 5 29 44 20 Connect to the main fluid supply line to the guns Connect to the main fluid return line 31 Ref 3 2 1 45 47 22 33 34 64 37 21 22 39 42 49...

Страница 14: ...r ready to catch the drainage 8 Leave the drain valve open until you are ready to spray again If you suspect that the spray tip or hose is completely clogged or that pressure has not been fully reliev...

Страница 15: ...tip in the gun 9 Use the air regulator to control the pump speed and fluid pressure Always use the lowest pressure necessary to achieve the desired results Higher pressures waste fluid and cause prem...

Страница 16: ...mping and with the wetted parts in your system Check with your fluid manufacturer or supplier for recommended flushing fluids and flushing frequency Always flush the pump before fluid dries on the dis...

Страница 17: ...0 157705 ADAPTER 1 4 npt m x 3 8 npsm f swivel 1 11 116401 ELBOW street 90 f 1 11 1 2 x 1 1 4 11 1 2 f zinc plated malleable iron 1 12 116402 ADAPTER f 1 11 1 2 x 1 1 4 11 1 2 f zinc plated malleable...

Страница 18: ...H55003 HOSE fluid nylon 1 2 in 12 7 mm ID 1 2 npt fbe 3 ft 0 9 m long 3 32 158683 ELBOW 90 1 2 npt m x f 2 33 156849 NIPPLE 3 8 npt 2 34 159801 UNION adapter 90 3 8 npt f x 1 2 npsm f swivel 2 35 1651...

Страница 19: ...heater 44 See Air Regulator Detail 5 See Check Valve Detail 6 5 15 16 17 8 18 14 19 AIR REGULATOR DETAIL Connect to the main fluid supply line to the guns Connect to the main fluid return line 1 2 7...

Страница 20: ...5 in 381 mm 8 5 in 216 mm 6 in 152 mm 5 in 127 mm 7 16 in diameter holes for pump wall bracket mount 5 ft 1 5 m above floor refer to 306783 for instructions M8 or 5 16 in diameter holes for heater wal...

Страница 21: ...fluid filter 3 8 npsm f Fluid inlet size 1 1 2 in npt f Weight Models 245187 253697 135 lb 61 kg Models 245185 245186 210 lb 95 kg Wetted parts Pump See pump manual 309340 Fluid Filter See manual 307...

Страница 22: ...y shall be as set forth above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or property or any oth...