The fluid port of the center manifold can be rotated to 
either a vertical or horizontal position. 

To change the fluid port orientation of the center 
manifold (113):

1.

Remove the manifold screws (120).

2.

Rotate the center manifold (113) to the applicable 
vertical or horizontal position. 

3.

Install the manifold screws (120) and torque to 50–
60 in-lb (5.65–6.78 N•m). See Torque Sequence
page 29.

KEY:

Fluid Pressure Relief Valve

Fluid Pressure Relief Valve 112119 (stainless steel) is 
available (purchase separately).

KEY:

R

Fluid inlet port

S

Fluid outlet port

V

Pressure relief valve

 Install valve between fluid inlet and outlet ports.

 Connect fluid inlet line here.

 Connect fluid outlet line here.

101

Fluid covers

120

Screw

113

Center manifold

F

IG

. 4: Fluid Inlet and Outlet Port Orientation

101

101

113

113

Apply medium-strength (blue) thread locker to the 
threads. Torque to 50–60 in-lb (5.65–6.78 N•m). See 
Torque Sequence, page 29.

1

1

1

1

1

120

120

120

120

Some systems may require installation of a pressure 
relief valve (V) at the pump outlet to prevent 
overpressurization and rupture of the pump or hose.

Thermal expansion of fluid in the outlet line can cause 
overpressurization. Thermal expansion can occur 
when using long fluid lines exposed to sunlight or 
ambient heat, or when pumping from a cool to a warm 
area (for example, from an underground tank).

Overpressurization also can occur if the pump is used 
to feed fluid to a piston pump, and the intake valve of 
the piston pump does not close, causing fluid to back 
up in the outlet line.

The pressure relief valve reduces the risk of serious 
injury, including splashing in the eyes or on the skin.

F

IG

. 5: Fluid Pressure Relief Valve

1

2

3

R

S

V

1

2

3

Содержание Aluminum Husky 2150 LP

Страница 1: ...t for use in sanitary applications For professional use only 120 psi 0 8 MPa 8 bar Maximum Fluid Working Pressure 120 psi 0 8 MPa 8bar Maximum Air Input Pressure See page 2 for model information inclu...

Страница 2: ...arts 26 Kits and Accessories 28 Torque Instructions 29 Torque Sequence 29 Performance Charts 30 Dimensions 31 Technical Specifications 32 California Proposition 65 33 Graco Standard Husky Pump Warrant...

Страница 3: ...only Do not alter or modify equipment Alterations or modifications may void agency approvals and create safety hazards Make sure all equipment is rated and approved for the environment in which you ar...

Страница 4: ...contain chemicals that can react with aluminum Contact your material supplier for compatibility TOXIC FLUID OR FUMES HAZARD Toxic fluids or fumes can cause serious injury or death if splashed in the e...

Страница 5: ...ible See Models page 2 or check with your local supplier ID Sample Configuration Number 2150LP PA01AA1FB BBNBN 2150 LP P A01A A1 FB B BN BN Pump Model Wetted Section Material Drive Center Section and...

Страница 6: ...y line J Fluid drain valve required not supplied K Fluid shutoff valve L Flexible conductive fluid outlet line N Air inlet port R Fluid inlet port S Fluid outlet port Y Ground wire 1 2 in npt f port F...

Страница 7: ...hind the grounding screw and tighten the screw securely Connect the clamp end of the ground wire to a true earth ground 02646E Y W Air and fluid lines Use only conductive lines with a maximum of 500 f...

Страница 8: ...diameter If a line longer than 15 ft 4 57 m is required use a larger diameter line Avoid sharp bends or kinks in the line 3 Place a conductive grounded container U at the end of the air exhaust line t...

Страница 9: ...V relieves fluid pressure in the fluid line See FIG 5 Fluid shutoff valve K shuts off fluid flow 1 Install flexible conductive fluid lines G and L 2 Install a fluid drain valve J in the fluid outlet l...

Страница 10: ...p relative to the liquid level in the supply b Reduce the friction length of the suction lines Remember that fittings add friction length to the lines Reduce the number of fittings to reduce the frict...

Страница 11: ...113 Center manifold FIG 4 Fluid Inlet and Outlet Port Orientation 101 101 113 113 Apply medium strength blue thread locker to the threads Torque to 50 60 in lb 5 65 6 78 N m See Torque Sequence page...

Страница 12: ...utlet line L to the fluid outlet port S and route the line to the end container 5 Close the fluid drain valve J 6 Turn the air regulator C to the lowest air pressure setting and open the bleed type ma...

Страница 13: ...Always cycle the equipment during the entire flushing process Always perform the Pressure Relief Procedure page 12 and flush the equipment before storing it for any length of time 1 Perform the Pressu...

Страница 14: ...d in Technical Specifications page 32 To aid with priming fill the chambers with liquid Equipment operates erratically Clogged suction line Inspect clear Sticky or leaking check valve flapper 116 Clea...

Страница 15: ...ipment leaks fluid externally from flapper check valves Over torqued center manifold bolts 120 causing the joint between the fluid cover 101 and manifolds 102 103 to separate Or loose joint between ma...

Страница 16: ...nents 4 Remove all check valve components and gaskets 121 NOTE Pay attention to the orientation of the check valve components for reassembly 5 Clean and inspect all parts for wear or damage Replace as...

Страница 17: ...24 9 N m See Torque Sequence page 29 1 119 118 117 116 112 115 114 114 115 112 116 117 118 119 121 121 Seat and check valve components Seat and check valve components 2 3 2 2 3 Apply medium strength b...

Страница 18: ...Replace as needed Reassemble Diaphragms 1 Assemble the diaphragm plates 104 105 packing o ring 108 and diaphragm 401 onto the diaphragm shaft bolt 107 See FIG 9 NOTE Install diaphragms 401 with the s...

Страница 19: ...Section Apply medium strength blue thread locker to the threads Torque to 190 220 in lb 21 25 N m See Torque Sequence page 29 1 2 Circular outlet hole must be at the base of the equipment 1 1 1 106 1...

Страница 20: ...diaphragms removed 1 2 105 5 107 3 401 7 104 4 24 19 1 402 1 Lips face out of housing 1 Rounded side faces diaphragm 401 AIR SIDE must face center housing 1 Grease Apply medium strength blue thread l...

Страница 21: ...e center position and pull it out of the cavity 5 Remove the valve block 7 and o ring 6 from the carriage 6 Use a needle nose pliers to pull the pilot block 18 straight up and out of the cavity See FI...

Страница 22: ...actuator pistons 11 Reach inside the cavity and insert the actuator pistons into the bearings 12 wide end first Leave the narrow end of the pistons exposed See FIG 12 9 Grease the lower face of the p...

Страница 23: ...earings 19 were removed reach into the center housing 1 with an o ring pick to hook the u cup packings 402 Remove u cup packings from the housing 9 Inspect parts for wear or damage Replace as necessar...

Страница 24: ...23 3 Insert bearings tapered end first 1 2 Press fit bearings flush with surface of center housing 1 Apply medium strength blue thread locker to the threads Torque to 120 150 in lb 14 17 N m 3 19 25...

Страница 25: ...Parts 3A8693B 25 Parts Air Section Parts 24 23 25 22 12 15 19 1 20 3 2 4 5 10 11 7 3 8 9 6 18 16 17 402...

Страница 26: ...Parts 26 3A8693B Fluid Section Parts 120 102 120 103 112 115 114 119 118 117 116 101 119 118 117 116 107 108 105 401 104 121 113 122 123 124 111 110 106 120 121 113 125...

Страница 27: ...escription Qty 101 20A298 COVER fluid aluminum 2 102 20A296 MANIFOLD inlet aluminum 1 103 20A297 MANIFOLD outlet aluminum 1 104 189298 PLATE air side aluminum 2 105 189820 PLATE fluid side carbon stee...

Страница 28: ...25U696 116 VALVE flapper 4 117 SPACER flapper 4 Kit No Includes Refs Description Qty 25U702 118 BRACKET flapper 4 119 SCREW cap socket head M6 x 1 0 30 mm 8 Kit No Includes Refs Description Qty 25U70...

Страница 29: ...orque sequence to turn down each fastener until the fastener head contacts the equipment 3 Follow the torque sequence to turn each screw by 1 2 turn or less until at specified torque Torque Sequence F...

Страница 30: ...ad air consumption A C B D 0 20 1 4 0 14 0 20 76 40 151 60 227 80 303 100 379 120 454 140 530 160 606 40 2 8 0 28 60 4 1 0 41 80 5 5 0 55 100 6 9 0 69 120 8 3 0 83 FLUID FLOW gpm lpm Pump tested in wa...

Страница 31: ...ver A B C D E F G H J K L M N in 23 31 20 86 17 73 3 16 13 40 6 70 23 29 11 64 13 81 17 69 11 01 13 95 8 89 mm 592 1 529 8 450 3 80 3 340 4 170 2 591 6 295 7 350 8 449 3 279 7 354 3 225 8 Dimensions c...

Страница 32: ...meters Wet 30 ft 9 14 meters Fluid flow per cycle Standard Diaphragms 1 gallon 3 79 liters Noise dBa Maximum sound pressure 90 dBa at 100 psi 0 69 MPa 6 9 bar at 50 cpm Inlet Outlet Sizes Air inlet s...

Страница 33: ...ost restricted wetted component Operating at a fluid temperature that is too high or too low for the components of your equipment may cause equipment damage Diaphragm Check or Seat Material Fluid Temp...

Страница 34: ...fect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER...

Отзывы: