Technical Data
U.S.
Metric
Maximum Fluid Working Pressure
250 psi
17 bar, 1.7 MPa
Air Inlet Pressure Range
30 to100 psi
2.1 to 6.9 bar, 0.2 to 0.7
MPa
Maximum Recommended Pump Speed
100 cycles/min, 2.5 gpm
delivery
100 cycles/min, 9.5
liters/min delivery
Pump Cycles per Gallon (3.8 Liters)
40
Ratio
2.5:1
Fluid Temperature Range
40 to 220°F4 to 104°C
Maximum Continuous Operating Temperature
180°F82°C
Maximum Ambient Temperature (Air Motor)
120°F49°C
Maximum size pumpable solids
1/8 in.
3.2 mm
Air Inlet
3/8 npt (f)
9.5 mm npt (f)
Air Exhaust
3/8 npt (m)
9.5 mm npt (m)
Fluid Inlet Size
Cylinder OD
2.0 in
5 cm
Inlet Seat ID
0.938 in
2.4 cm
Fluid Outlet
1 in. Tri-clamp®
2.5 cm Tri-clamp®
Sound Power*
73.4 at dBA at 70 psi and
20 cpm
73.4 dBA at 4.8 bar and 20
cpm
Sound Pressure*
65.4 at dBA at 70 psi and
20 cpm
65.4 dBA at 4.8 bar and 20
cpm
Weight
Models 24R046 and 24R047
24 lb
10.9 kg
Models 24N300 and 24N344
26 lb
11.8 kg
Wetted Parts
300 Series Stainless Steel, Acetal, PTFE, FKM, UHMWPE
* Sound power measured per ISO-9614–2. Sound pressure was tested 3.28 ft (1 m) from equipment.
3A2977K
27