background image

Maintenance

Maintenance

Flushing Procedure

Note:
• Flush before fluid can dry in the equipment, at the

end of the day, before storing, and before repairing

equipment.

• Flush at the lowest pressure possible. Check

connectors for leaks and tighten as necessary.

• Flush with an appropriate cleaning solution.
1. Follow

Pressure Relief Procedure, page 8

.

2. Remove the pump from the fluid container. Place

it in an empty drum. Operate it to pump out as

much fluid as possible.

3. Place siphon tube in grounded metal pail

containing an appropriate cleaning solution.

4. Set pump air regulator to lowest possible fluid

pressure, and start pump.

5. Run the pump long enough to thoroughly clean

the pump and hoses.

6. Follow

Pressure Relief Procedure, page 8

.

Cleaning

• Be sure to follow your national and state sanitary

standard codes and local regulations.

• Use appropriate cleaning and disinfecting agents,

at intervals appropriate for product processed.

• Follow cleaning product manufacturer’s

instructions.

Note: The pump lower must be disassembled to

thoroughly clean it.
1. Follow the

Pressure Relief Procedure, page 8

.

2. Remove the pump from the fluid container. Place

it in an empty drum Operate it to pump out as

much fluid as possible.

3. Flush the system thoroughly with an

appropriate cleaning solution. See

Flushing Procedure, page 9

.

4. Follow the

Pressure Relief Procedure, page 8

.

5. Remove the air and fluid hoses and fittings from

the pump.

6. Disassemble the fluid pump and accessories.

See

Disassemble the Pump, page 15

.

7. Wash all pump parts with an appropriate cleaning

solution at the cleaning product manufacturer’s

recommended temperature and concentration.

8. Rinse all pump parts again with water and allow

them to dry.

9. Inspect all pump parts and reclean if needed.

Note

Any damaged rubber parts must

be replaced as they could harbor

microorganisms that can contaminate

the fluid.

10. Immerse all pump parts in an appropriate

sanitizer before assembly. Take the pump parts

out of the sanitizer one-by-one as needed.

11. Lubricate the moving pump parts and o-rings,

packings, and seals with appropriate waterproof

sanitary lubricant.

12. Circulate the sanitizing solution through the pump

and the system prior to use.

Tighten Threaded Connections

Before each use, check all hoses for wear or damage.

Replace as necessary. Check that all connections

are tight and leak-free.

3A2977K

9

Содержание 3A2977K

Страница 1: ...s to transfer low to medium viscosity uids Use with non ammable liquids only For professional use only Important Safety Instructions Read all warnings and instructions in this manual Save these instru...

Страница 2: ...Down 8 Maintenance 9 Flushing Procedure 9 Cleaning 9 Tighten Threaded Connections 9 Troubleshooting 10 Repair 11 Disconnect the Air Motor 11 Air Motor Disassembly 11 Air Motor Reassembly 13 Disassemb...

Страница 3: ...um Length 42 in 107 cm Drum U Cup PTFE 24R046 Double Ball Standard Drum Length 34 in 86 cm Drum U Cup UHMWPE 24R047 24R047C31 Double Ball Standard Drum Length 34 in 86 cm Drum U Cup PTFE NOTE See page...

Страница 4: ...er or light switches on or off when ammable fumes are present Ground all equipment in the work area See Grounding instructions Use only grounded hoses Hold gun rmly to side of grounded pail when trigg...

Страница 5: ...om traf c areas sharp edges moving parts and hot surfaces Do not kink or over bend hoses or use hoses to pull equipment Keep children and animals away from work area Comply with all applicable safety...

Страница 6: ...ounting Mount the pump to fully support the weight of the pump and accessories as well as the stress caused during operation Do not use air or uid lines to support the pump Setup To avoid contaminatin...

Страница 7: ...g exhaust hose ref M G Bleed type master air valve required C 3 8 npt exhaust air outlet H Air line drain pipe and valve D 3 8 npt air inlet J Main air line K Pump ground wire required Graco PN 238909...

Страница 8: ...y pump was assembled using sanitary lubricant on moving parts and was tested in water Flush the pump thoroughly with an appropriate cleaning solution or disassemble and sanitize the parts before using...

Страница 9: ...ocedure page 8 2 Remove the pump from the uid container Place it in an empty drum Operate it to pump out as much uid as possible 3 Flush the system thoroughly with an appropriate cleaning solution See...

Страница 10: ...seat or seals Pump dives and or does not pump on downstroke Fluid inlet is obstructed Clear obstructions away from inlet Raise pump off of drum bottom Pump cycles unevenly or erratically Air motor is...

Страница 11: ...splacement pump straight up and out of the container Air Motor Disassembly 1 Use ats on the base 118 to clamp the air motor into a vise 2 Remove the motor cover 10 3 Remove cap 103 Use a large channel...

Страница 12: ...low these steps to replace the entire air valve without disassembly a Purchase Kit 262035 to replace entire valve assembly b Clamp piston in a vice Hold the piston cap with a spanner wrench and unscre...

Страница 13: ...threads are sharp Always wear protective gloves to prevent cuts 1 If the bushing 119 was removed use an arbor press and seat it all the way into the air motor base 118 Alternate tapping using a hammer...

Страница 14: ...d 115 Use pipe sealant on the threads of the valve 105 and torque to 15 to 20 ft lb 20 3 to 27 1 N m Use a screwdriver as shown if needed Torque to 15 to 20 ft lb 20 to 27 N m 9 Grease the inside and...

Страница 15: ...he way out 2 Use a screwdriver in the slot to remove the inlet valve assembly Remove the retaining pin 212 and ball 213 Push the seat 210 out the bottom of the inlet housing 209 Remove o rings 211 and...

Страница 16: ...all o rings 218 on the seat assembly Install the ball 207 then the seat assembly in the outlet housing 2 Lubricate and install one o ring 208 in the groove on the outlet seat pin 206 Push the pin 206...

Страница 17: ...ond side The ends of the pin should be ush to the outside of the cylinder Check that the o rings are seated in the grooves Reconnect The Pump 1 If using bung adapter Accessory Kit 24R650 install it in...

Страница 18: ...Parts Parts Apply sanitary grease before assembling cover 18 3A2977K...

Страница 19: ...d on Pump Model 24N344 24R192 Used on Pump Model 24R046 6 24R191 Used on Pump Model 24R047 1 7 112933 MUFFLER 1 Ref Part Description Qty 10 24R178 COVER motor includes o ring ref 123 1 14 16U653 TOOL...

Страница 20: ...R180 Torque to 50 to 60 in lb 5 6 to 6 8 N m Apply sanitary lubricant Apply medium strength thread locker Torque to 15 to 20 ft lb 20 3 to 27 1 N m Torque to 20 to 30 in lb 2 3 to 3 4 N m Apply pipe s...

Страница 21: ...FKM 1 118 16P900 BASE air motor 1 119 BUSHING air motor included with air piston assembly ref 124 1 Ref Part Description Qty 120 159846 O RING buna N 1 121 16P926 RETAINER o ring 1 122 15J551 SPRING c...

Страница 22: ...Parts Displacement Pump Models 24R189 24R190 24R191 and 24R192 Apply sanitary lubricant 22 3A2977K...

Страница 23: ...195 and 24R196 10 209 17A630 GUIDE ball inlet 316 stainless steel 1 210 16P132 SEAT inlet sold with ball ref 213 and o ring ref 211 in Kit 24R182 1 Ref Part Description Qty 211 O RING 125 FKM sold wit...

Страница 24: ...ing 104 pin 109 and o ring 126 24R176 Air Motor Piston Kit Piston with cap and o ring 124 factory assembled bushing 119 and o ring 120 24R177 Air Inlet Outlet Fitting Kit Inlet outlet tting 125 and o...

Страница 25: ...cm in cm A 61 9 157 2 54 9 139 4 B 53 7 136 4 46 7 118 6 C 44 5 113 0 37 5 95 2 D uid inlet OD 1 972 5 0 1 972 5 0 E air inlet 3 8 npt f 9 5 npt f 3 8 npt f 9 5 npt f F air exhaust 3 8 npt m 9 5 npt...

Страница 26: ...28 12 0 33 14 0 39 50 0 3 3 100 0 7 7 150 1 0 10 200 1 4 13 250 1 7 17 300 2 1 21 0 0 5 1 9 1 0 3 8 1 5 5 7 2 0 7 6 2 5 9 5 0 20 40 60 80 100 A B C A B C Air Flow scfm m3 min Fluid Flow gpm lpm KEY A...

Страница 27: ...otor 120 F 49 C Maximum size pumpable solids 1 8 in 3 2 mm Air Inlet 3 8 npt f 9 5 mm npt f Air Exhaust 3 8 npt m 9 5 mm npt m Fluid Inlet Size Cylinder OD 2 0 in 5 cm Inlet Seat ID 0 938 in 2 4 cm Fl...

Страница 28: ...for lost pro ts lost sales injury to person or property or any other incidental or consequential loss shall be available Any action for breach of warranty must be brought within two 2 years of the da...

Отзывы: