Remote Display Module Screens
Temperature Screen
Use this screen to view the actual and target
temperatures for A material, B material, heated hose
at the gun, and estimated drum level.
At this screen you can turn on heat zones and make
minor adjustments to the temperature and pressure
as the ambient temperature, drum temperature,
and other environmental variables change over the
course of the spray day.
Turn on a heat zone: Press one of the softkey
buttons to turn on or off the corresponding heat zone.
Adjust temperature setpoint: Press
and use the
left and right arrow keys to select which temperature
setpoint you want to modify. Press the up and down
arrows to change the temperature.
Icon
Function
Press to edit the temperature
setpoints.
Press to enable or disable the
A component heat zone.
Press to enable or disable the
B component heat zone.
Press to enable or disable the
heated hose heat zone.
Indicates that the heat zone
is on. A blank box indicates
that the heat zone is off.
Pressure Screen
Use this screen to view actual pressures for A and B
components at the fluid manifold, A and B pressure
setpoint, number of cycles, number of flow units
pumped, estimated drum level, and park the pumps.
Adjust pressure setpoint: Press
. Press the up
and down arrows to change the pressure.
Icon
Function
Press to edit the pressure
setpoint.
Press to park the system
pumps.
Press to start proportioner.
Press to stop proportioner.
Press to clear cycle counter
3A1907C
5