Repair
6
3A0239F
Repair
Replace Power Supply
1.
Turn off system power.
2.
Open electrical enclosure door.
3.
Disconnect power supply (1a) wires from the filter
(1c) and the electrical enclosure connector.
4.
Remove nuts and washers that secure power supply
to electrical enclosure.
5.
Install new power supply to electrical enclosure.
Secure with nuts and washers.
6.
Connect power supply wires to the filter and the
electrical enclosure connector.
7.
Close electrical enclosure door and turn on system
power.
Replace Circuit Breaker
1.
Turn off system power.
2.
Open electrical enclosure door.
3.
Disconnect wire harness from circuit breaker.
4.
Remove circuit breaker.
5.
Install new circuit breaker, and connect wire har-
ness.
6.
Close electrical enclosure door and turn on system
power.
1c
Connector
r_24C680_3A0239_10a
1a
Wire Harness
Wire Harness
Circuit Breaker
r_24C686_3A0239_2a
Содержание 3A0239F
Страница 7: ...Electrical Schematics 3A0239F 7 Electrical Schematics 230V 1 Phase Basic HFR Module Schematic...
Страница 8: ...Electrical Schematics 8 3A0239F 230V 1 Phase Loaded HFR Module Schematic...
Страница 9: ...Electrical Schematics 3A0239F 9 230V 3 Phase Basic HFR Module Schematic...
Страница 10: ...Electrical Schematics 10 3A0239F 230V 3 Phase Basic VRM Module Schematic...
Страница 11: ...Electrical Schematics 3A0239F 11 230V 3 Phase Loaded HFR Module Schematic...
Страница 12: ...Electrical Schematics 12 3A0239F 230V 3 Phase Loaded VRM Module Schematic...
Страница 13: ...Electrical Schematics 3A0239F 13 400V 3 Phase Basic HFR Module Schematic...
Страница 14: ...Electrical Schematics 14 3A0239F 400V 3 Phase Basic VRM Module Schematic...
Страница 15: ...Electrical Schematics 3A0239F 15 400V 3 Phase Loaded HFR Module Schematic...
Страница 16: ...Electrical Schematics 16 3A0239F 400V 3 Phase Loaded VRM Module Schematic...
Страница 27: ...Parts 3A0239F 27 ti18048a 25 26 29 61 28 27 24 71 71 20 70 70 1b 1c 1a...
Страница 29: ...Parts 3A0239F 29...