Instruction Manual

 

 

Basic Rack PDU VP7557

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VertivCo.com/geist

 

 

Summary of Contents for VP7557

Page 1: ...Instruction Manual Basic Rack PDU VP7557 VertivCo com geist ...

Page 2: ...ew 3 1 2 Environmental 3 1 2 1 Temperature 3 1 2 2 Humidity 3 1 2 3 Elevation 3 1 3 Electrical 3 1 4 Receptacle Ratings 3 2 Installation 5 2 1 Instructions 5 2 2 Guidelines 5 3 Mounting 6 4 Service Tech Support 10 4 1 Service and Maintenance 10 4 2 More Technical Support 10 5 Revision 10 ...

Page 3: ...distributed through the output receptacles to connected equipment 1 2 ENVIRONMENTAL 1 2 1 TEMPERATURE Operating 10 C 50 F min 45 C 113 F max Storage 25 C 13 F min 65 C 149 F max 1 2 2 HUMIDITY Operating 5 min 95 max non condensing Storage 5 min 95 max non condensing 1 2 3 ELEVATION Operating 0 m 0 ft min 2000 m 6561 ft max Storage 0 m 0 ft min 15240 m 50000 ft max 1 3 ELECTRICAL See nameplate for ...

Page 4: ...Basic Rack PDU VP7557 Instruction Manual Page 4 Receptacle ratings give nameplate component voltage and current ratings All Y Series PDUs have output receptacles wired for 230 Vac Line Neutral Output ...

Page 5: ...ot compromised Mount the PDU so that a hazardous condition is not achieved due to uneven mechanical loading Follow nameplate ratings when connecting equipment to the branch circuit Take into consider ation the effect that overloading of the circuits might have on over current protection and sup ply wiring The PDU relies on the building installation for protection from over current conditions A cer...

Page 6: ... Rack PDU VP7557 Instruction Manual Page 6 3 MOUNTING Full Length Bracket Using the full length bracket mount PDU to rack as shown Mini L Brackets SLB 4 Using the mini L brackets attach PDU to rack as shown ...

Page 7: ... Brackets VCB 1 Using the vertical extension brackets attach PDU to rack as shown Toolless Mounting Hardware 11621 Secure toolless mounting buttons to PDU as shown Use toolless buttons with key holed slots built into cabinet or with optional Vertiv key holed brackets ...

Page 8: ...s Full Length Bracket TLFL Using full length toolless bracket and toolless mounting buttons attach PDU to rack as shown Single Side Mount 2 Unit Brackets TSMX2 Using single side mount 2 unit brackets and toolless mounting buttons attach PDU to rack as shown ...

Page 9: ... VP7557 Instruction Manual Page 9 Offset Side Mount Brackets EZB 1 Using the offset side mount brackets attach PDU to rack as shown 7 Extension Brackets XB 7 Using the 7 extension brackets attach PDU to rack as shown ...

Page 10: ...m geist Phone Support 1 800 432 3219 Email support VertivCo com or contact your distributor Technical Support Form VertivCo com Tech Support 5 TECHNICAL SUPPORT FORM VERTIVCO COM TECH SUPPORT REVISION Revision Date Notes Approved By 1 0 4 8 2009 Original Published Version BP 1 1 7 1 2009 Added Link Speed Information BP 1 2 6 30 2010 Updated Current Monitoring Meter Name BP 1 3 1 24 11 Added Satell...

Page 11: ...Basic Rack PDU VP7557 Instruction Manual Page 11 KEYWORD INDEX No index entries found ...

Page 12: ...Basic Rack PDU VP7557 Instruction Manual Page 12 Thank You For Purchasing Your Vertiv Product VertivCo com geist ...