![Graco 333586E Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/graco/333586e/333586e_installation-manual_2251271020.webp)
Supply Unit Component Identification
20
333586E
Installing Tandem
1. Remove cable from port C1 on ram 1 and plug into
female end of splitter. Splitter is included in tandem
kit.
2. Install 0.4 m cable (121226) included in tandem kit
from male end of splitter to part C1 on ram 1.
3. Install 5.0 m cable (124003) included in the tandem
kit, from male end of splitter and connect to part C1
of ram 2.
4. Use zip ties included in kit to secure cables to ram
NOTE
: Ram 1 includes ADM, ram 2 has no ADM.
Key:
Port 1 Connects to port C1 on the Power Junction Box.
Port 2 Connects to port C2 on the Power Junction Box.
Port 3 Connects to port C3 on the Power Junction Box (M12 5 pin), and to the platen valve solenoid (M8 4 pin).
Port 4 Connects to port C4 on the Power Junction Box, and to the Tandem Block (R) solenoid splitter (M8 4 pin).
Port 5 Connects to the pump pressure transducer.
Port 6 Connects to the valve pressure transducer splitter on the Tandem Block (R).
F
IG
. 10: Communication Connections
A
K
ADM
C1
Cable from Tandem Kit
Splitter from Tandem Block
Содержание 333586E
Страница 96: ...Wiring Diagrams 96 333586E Wiring Diagrams...
Страница 97: ...Wiring Diagrams 333586E 97...
Страница 98: ...Wiring Diagrams 98 333586E...