background image

Installation 

6

311304H

Installation

When unpacking pump, check for shipping damage. 
Report any shipping damage to delivering carrier imme-
diately. 

Mounting Pump

1. Apply PTFE thread tape (provided with the pump) to 

large thread of bung adapter (9) (2 in. X 1 ½ in. 
reducer fitting). Install bung adapter to fuel tank.

2. Assemble suction tube sections by applying ¼ in. to 

½ in. wide bead of PVC cement (PN: 260086; white 
tube provided with the pump) around the entire 
inside diameter of the coupler (see F

IG

. 1). While 

sliding the tube into the couplers turn the tube at 
least one full revolution until the tube bottoms out on 
the coupler (see F

IG

. 2, F

IG

. 3, and F

IG

. 4). This will 

allow the cement to coat the entire surface for the 
best possible seal. Allow cement to set for 5 min-
utes minimum before installing pump into tank.

CAUTION

Do not use a curb pump automatic shut-off nozzle 
with this pump. Use of a curb pump automatic nozzle 
may cause priming problems, reduced output flow, 
and motor overheating. If an automatic shut-off nozzle 
is required, use Graco part number 260082 (regular) 
or 260083 (unleaded) or Catlow, Inc. part number 
NCLF-1 (regular) or NCNLF-1 (unleaded).

CAUTION

Ensure tank being used is clean and free of welding 
slag

 

Ensure the tank is vented to allow air into the tank 
as the fuel is being pumped out. Failure to provide a 
vent will cause priming problems

For tanks deeper than 36 in. (914 mm) you will 
need a standard 1 in. (25 mm) pipe with 1 in. npt 
threads on one end. Suction tubes longer than 60 
in. (1.52 m) require a foot valve (Graco Part No. 
260217) at the bottom of the tube to prevent loss of 
prime.

F

IG

. 1

F

IG

. 2

F

IG

. 3

F

IG

. 4

Содержание 260000

Страница 1: ...sted motor Models 260020 and 260021 10 gpm 38 lpm 24 VDC Models 260022 and 260023 12 gpm 45 lpm 230 VAC Models 260025 through 260028 12 gpm 45 lpm 115 VAC CSA C US listed motor 10 psi 0 07 MPa 0 7 bar...

Страница 2: ...0078 manual unleaded 260013 260525 5 ft 1 52 m UL listed assembly 260078 manual unleaded 260014 260525 5 ft 1 52 m UL listed assembly 260078 manual unleaded 260015 260523 8 ft 2 44 m UL listed assembl...

Страница 3: ...Models 311304H 3...

Страница 4: ...t use equipment until you identify and correct the problem Keep a fire extinguisher in the work area ELECTRIC SHOCK HAZARD Improper grounding setup or usage of the system can cause electric shock Turn...

Страница 5: ...MSDS forms from distributor or retailer Check equipment daily Repair or replace worn or damaged parts immediately with genuine Graco replacement parts only Do not alter or modify equipment Use equipme...

Страница 6: ...st possible seal Allow cement to set for 5 min utes minimum before installing pump into tank CAUTION Do not use a curb pump automatic shut off nozzle with this pump Use of a curb pump automatic nozzle...

Страница 7: ...ition pump as desired and tighten union nut 1k on bung adapter 9 Mounting Hose and Nozzle 1 Apply thread tape provided with pump to both ends of hose assembly Screw NPT end of 90 union swivel 15 to on...

Страница 8: ...rical connection 13 Connect red wire with fuse holder inline to positive battery terminal Connect black wire to negative bat tery terminal Electrical Installation 115 VAC and 230 VAC 1 Ensure pump swi...

Страница 9: ...m the pump outlet out to the fuel nozzle Any leaks after the outlet will allow air to push the fluid column back to the tank and prime will be lost 2 If no leaks are detected on the outlet side of the...

Страница 10: ...trainer 3b clogged Remove and clean or replace Air leak in suction tube Inspect all joints in suction tube Make sure all joints in suction tube are sealed and that there are no cracks from over tighte...

Страница 11: ...a binding Check to make sure gears turn freely on shaft Operating pump extended time with nozzle closed Do not exceed 5 minutes of operation with nozzle closed Clogged inlet strainer 3b Clean or repla...

Страница 12: ...00 through 260017 260019 260024 260580 and 260581 12 VDC Models 260020 and 260021 24 VDC Models 260022 and 260023 230 VAC Models 260025 through 260028 115 VAC 1j 260450 260451 260452 260453 260457 260...

Страница 13: ...21 KIT motor 115 VAC black includes items 2a 2i 253722 KIT motor 230 VAC black includes items 2a 2i 2a COVER electrical 1 2b HOUSING electrical 12 V 1 2c BOLT hex 1 4 20 x 3 4 in 10 2d NUT 10 32 2 2e...

Страница 14: ...C and 24 VDC models only Ref No Description Qty 8 260433 KIT switch blue includes items 8a 8g 253718 KIT switch black includes items 8a 8g 8a COVER switch 1 8b BRACKET switch 1 8c CAM actuator switch...

Страница 15: ...e 18 ft 5 5 m 14 AWG 12 VDC and 24 VDC models only Current draw 12 VDC models 12 5 amps 24 VDC models 7 amps 115 VAC models 2 amps 230 VAC models 1 amps Duty cycle 30 min hour Suction tube 1 in x 34 i...

Страница 16: ...rkmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR...

Отзывы: