Troubleshooting
3A5541D
13
Troubleshooting
For information on troubleshooting a Reactor, refer to
the Reactor repair manual.
Disconnect Cellular Module
NOTE:
Before troubleshooting the Reactor, disconnect
the cellular module (A). The Reactor 2 App cannot
change Reactor 2 settings while the cellular module is
disconnected.
1.
Shut down system. See your Reactor 2 operation
manual for shutdown instructions.
2.
Disconnect incoming power at the source.
3.
Disconnect the cellular module CAN cable (C) from
the ADM.
4.
Disconnect the power supply cable (D) from the
cellular module (A) and connect the power supply
cable to the ADM.
Problem
Cause
Solution
No module status LEDs are
illuminated.
No power to cellular module.
Turn Reactor proportioner on.
Ensure cellular module is properly
installed. See
No network connection.
Still establishing cellular connection.
Wait a few minutes for the unit to
establish a connection.
Unable to establish cellular
connection.
To establish cellular connection, move
system to a location with cellular
service.
Mount accessory antenna 25D878 on
the outside of your trailer.
Network is connected, but there is no
server connection.
Cellular module software is incorrect. Go to ADM Advanced Software
screen and confirm that software is
correct. If it is not, update the ADM
software.
Server is not responding.
Wait a few minutes for the unit to
establish a connection.