Overview
The inlet pressure transducer kit enables the inlet
pressure reading to be displayed on the ADM screen for
easy viewing. This kit also enables the EFR system to
detect when high or low inlet pressure may inhibit
performance.
Installation
1. Ensure the system power is OFF and pressure has
been relieved. Follow the Pressure Relief Procedure
in the Electric Fixed Ratio Proportioner, Setup -
Operation manual.
2. Remove the pump yoke shroud (J) and frame cover
(K) from the EFR system.
Manual
Description
3A6165
Electric Fixed Ratio Proportioner, Setup -
Operation
406987
GCA CAN Cables, Reference
Ref. Part
Description
Qty
.
A
---
MODULE, inlet transducer
monitor
1
AA ---
MODULE, FCM
1
AB ---
BRACKET, mounting
1
B
127068
CABLE, CAN, 1.0M
1
C
102598
SCREW, cap, socket head
2
D
---
WASHER, nylon blk
2
E
15M669
SENSOR, pressure, fluid outlet
2
F
16U440
ADAPTER, fitting, pressure
sensor
2
G
121399
PACKING, o-ring
2
H
---
CABLE TIE
12
WARNING
ELECTRIC SHOCK HAZARD
To avoid electric shock, make sure the
system power is OFF before connecting or
disconnecting CAN cables.
PRESSURIZED FLUID HAZARD
This equipment stays pressurized until
pressure is manually relieved. To help
prevent serious injury from pressurized
fluid, such as skin injection, splashing fluid
and moving parts, follow the Pressure
Relief Procedure when you stop spraying
and before cleaning, checking or servicing
the equipment.
PERSONAL PROTECTIVE EQUIPMENT
Wear appropriate protective equipment
when in the work area to help prevent
serious injury, including eye injury, hearing
loss, inhalation of toxic fumes, and burns.