Overview
Coolant only flows through the secondary heat
exchangers when the heat exchanger control valves
(VA, VB) are open and the A and B component
temperatures are below the target temperatures set
on the ADM. See Fig. 24.
When the control valves (VA, VB) close, the A
and B material has reached target temperature.
Coolant flows through the bypass control valve (VC),
circulation pump (CP), sight glass (SG), proportioner
coolant fill bottle (HF), and back to the heat exchanger
in the engine coolant loop. See Fig. 23
HE
SG
CP
VC
VB
VA
HE
Proportioner Coolant Loop — A and B Valves Closed
(not heating material)
Figure 23
SG
CP
VC
VB
VA
HE
HE
Proportioner Coolant Loop — A and B Valves Open
(heating material)
Figure 24
32
3A1705E
Содержание 259079
Страница 34: ...Setup A5 A1 A2 AS AN A3 AT A3 A4 A2 A6 A4 34 3A1705E...
Страница 45: ...Advanced Display Module ADM Operation Setup Screens Navigation Diagram Figure 35 3A1705E 45...
Страница 49: ...Advanced Display Module ADM Operation Run Screens Navigation Diagram Figure 36 3A1705E 49...
Страница 93: ...Dimensions Dimensions Top View Figure 43 Side View Figure 44 3A1705E 93...
Страница 95: ...Dimensions Pallet Mounting Dimensions Figure 48 3A1705E 95...
Страница 97: ...Notes Notes 3A1705E 97...