Graco 257815 Скачать руководство пользователя страница 2

 

2

313768B

Disassembly

1.

Relieve Pressure (see cover) and unplug sprayer.

2.

Remove shroud and compressor:

a.

Loosen IEC cord clamp screw and remove IEC 

plug from compressor.

b.

Remove air hose from compressor and remove 

outlet fitting from compressor.

c.

Remove four screws. Tip compressor assembly 

down and forward to remove from sprayer. 

Place compressor on workbench.

d.

Remove two screws and IEC cord clamp. 

Remove two screws and compressor shroud.

3.

Remove cooling tube (71) by loosening cooling tube 
nuts (70).

4.

Use 1/2 in. socket to remove three bolts (100) from 
head (74).

5.

Use flat-blade screwdriver to pry head (74) from top 
of plate (75) and cylinder (76) from bottom of valve 
plate (75).

6.

Use 7/32 in. allen wrench to remove hex screw (87) 
from piston rod (77).

ti13409a

ti13411a

ti13416a

ti13664a

ti13414a

ti13941a

100

74

75

76

71

70

70

ti13940a

87

77